Detailed Screen With Values; Turning Operation On Or Off; Visual Indication; To Turn On Or Off - Daikin Altherma 3 M EDLA09-16D3V3 Operation Manual

Table of Contents

Advertisement

Item
Minimum temperature limit
Maximum temperature limit
Current temperature
Desired temperature
Submenu
5.3.4

Detailed screen with values

a
c
b
a
Settings
b
Values
c
Selected setting and value
Possible actions on this screen
Go through the list of settings.
Change the value.
Go to the next setting.
Confirm changes and proceed.
5.4

Turning operation ON or OFF

5.4.1

Visual indication

Certain functionalities of the unit can be enabled or disabled
separately. If a functionality is disabled, the corresponding
temperature icon in the home screen will be greyed out.
Space heating/cooling operation
a
55
45
21
35
a
Space heating/cooling operation ON
b
Space heating/cooling operation OFF
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620243-1B – 2021.02
Description
a1
Fixed by the unit
a2
Restricted by the installer
b1 Fixed by the unit
b2 Restricted by the installer
c
Measured by the unit
d
Turn the right dial to
increase/decrease.
e
Turn or press the left dial to
go to the submenu.
Example:
7.2.1
Time/date
Hours
11
30
Minutes
a
c
b
b
55
45
21
35
Tank heating operation
c
55
45
21
35
c
Tank heating operation ON
d
Tank heating operation OFF
5.4.2

To turn ON or OFF

Space heating/cooling operation
NOTICE
Room frost protection. Even if you turn OFF space
heating/cooling operation ([C.2]: Operation > Space
heating/cooling), room frost protection operation –if
enabled– can still activate. However, for leaving water
temperature control and external room thermostat control,
the protection is NOT guaranteed.
NOTICE
Water pipe freeze prevention. Even if you turn OFF
space heating/cooling operation ([C.2]: Operation >
Space heating/cooling), water pipe freeze prevention –
if enabled– will remain active.
1 Go to [C.2]: Operation > Space heating/cooling.
C.2
Operation
Space heating/cooling
On
Tank
Off
2 Set operation to On or Off.
Tank heating operation
NOTICE
Disinfection mode. Even if you turn OFF tank heating
operation ([C.3]: Operation > Tank), disinfection mode will
remain active. However, if you turn it OFF while
disinfection is running, an AH error occurs.
1 Go to [C.3]: Operation > Tank.
C.3
Operation
Space heating/cooling
On
Tank
Off
2 Set operation to On or Off.
5.5

Reading out information

To read out information
1 Go to [8]: Information.
5 Operation
d
55
45
21
35
Operation manual
11

Advertisement

Table of Contents
loading

Table of Contents