Control Cavity Access
Tools needed: Protective gloves, multi-purpose tool
• Remove decorative barrier front.
• Remove fixed glass assembly.
• Remove glass seal plate. See Figure 4.3.
• For easier access, glass clip assemblies can be removed.
See Figure 4.5. Be careful when handling base refractory.
Note: Bottom right glass clip on 25 inch models must be
removed to gain access to controls.
• For access, slide out component tray. See Figure 4.4.
Note: Wires may need to be removed from clips for full
access. See Figure 4.4.
PRESS
TAB TO
RELEASE
UNCLIP
WIRES
GLASS SEAL PLATE
COMPONENT TRAY
WITH HEAT SHIELD
Figure 4.4 Component Tray Access
CAUTION: Be sure to reinstall the component heat shield
before firing the appliance. Components will overheat
without the heatshield in place.
CAUTION: Be sure to reinstall wires into the retaining clips.
Majestic • TRILLIANT25IN, TRILLIANT30IN, TRILLIANT35IN Owner's Manual • 2571-981 Rev. B • 5/23
COMPONENT
TRAY RECEIVER
COMPONENT
TRAY
GLASS SEAL PLATE
BASE REFRACTORY
GLASS CLIP
ASSEMBLIES
Figure 4.5 Glass Clip Removal
GLASS
CLIP ASSEMBY
SCREW ACCESS