Heater Assembly Or Burner Does Not Shut Off; Clothes Do Not Dry; Signal Does Not Operate Correctly - Maytag Amana NDE2330AYW Service Manual

Home laundry dryers
Table of Contents

Advertisement

Troubleshooting Procedures
To avoid risk of electrical shock, personal injury, or death, disconnect power to dryer and shut-off gas supply
before servicing, unless testing requires it.

11. Heater assembly or burner does not shut off.

Possible Cause
Improper motor switch. (Timer must be in a
heat cycle).
Motor does not stop.
Heater assembly shorted.
Broken, loose or incorrect wiring.

12. Clothes do not dry.

Possible Cause
Too much water left in articles being dried.
Dryer is overloaded.
Clogged lint filter.
Load too small.
Automatic cycle.
Selector switch or timer incorrectly set or
failed.
Heater assembly or burner shuts off
prematurely.
Improper or inadequate exhaust system.
Weather hood flapper maybe restricted.
Failed moisture sensing control.
Belt not installed properly on pulley.
Gas line pressure too high or too low.

13. Signal does not operate correctly.

Possible Cause
Failed moisture sensing control.
Failed electronic control board.
Failed signal selector switch.
Failed adjustable buzzer.
Failed timer.
©2004 Maytag Services
!
W ARNING
• Test motor switch and replace if failed.
• See "Internal Motor Diagram and Schematic".
• Test heater assembly and replace if failed.
• Refer to appropriate wiring diagram for correct wiring.
• Remove excess water from clothing.
• Remove part of the load. A normal washer load is a normal dryer
load. Maximum load is ½ of the dryer cylinder with wet clothes.
• Clean lint filter.
• Add one or two bath towels to the load.
• Adjust timer to MORE DRY setting.
• Reset selector switch or timer.
• Test selector switch and timer and replace if failed.
• See Troubleshooting Procedure (# 9. Heater assembly or burner
shuts off prematurely).
• See "Installation Instructions" for exhaust requirements.
• Test moisture sensing control and replace if failed.
• Verify cylinder belt is installed correctly.
• Verify pressure to unit. If natural gas pressure exceeds 8 WCP and
is lower than 4 WCP, refer consumer to contact gas company.
• Test moisture sensing control and replace if failed.
• Test electronic control board and replace if failed.
• Test signal selector switch and replace if failed.
• Test adjustable buzzer and replace if failed.
• Test timer and replace if failed.
16023020
Result
Result
Result
17