10. Repairs
Repairs to electrical tools must only be carried
out by qualified electricians!
A defective mains cable must be replaced only with
a special, original mains cable from Metabo
available from the Metabo service.
Contact your local Metabo representative if you
have Metabo power tools requiring repairs. For
addresses see www.metabo.com.
You can download a list of spare parts from
www.metabo.com.

11. Environmental Protection

Observe national regulations on environmentally
compatible disposal and on the recycling of disused
machines, packaging and accessories.
Only for EU countries: never dispose of
power tools in your household waste!
According to European Directive 2012/19/EU
on Waste from Electric and Electronic Equipment
and implementation in national law, used power
tools must be collected separately and recycled in
an environmentally-friendly manner.

12. Technical Specifications

HG 16-500
Output:
1600 W
Air temperature:
Stage 1: ..................... 300 °C
Air volume:
stage 0: ............................ off
Stage 1: ..................240 l/min
Stage 2: ..................450 l/min
Thermal protection: only thermal fuse
Weight
600 g (20.8 oz)
Sound pressure level:< 70 dB (A)
Vibration:
< 2.5 m/s
HG 20-600
Output:
2000 W
Air temperature:
Stage 2: ............. 80-600 °C
Stage 3: .............. 80-600 °C
Air volume:
stage 0: ...........................off
Stage 1: ................ 150 l/min
Stage 2: ................ 300 l/min
Stage 3: ................ 500 l/min
Temperature
Setting:
stepless in 9 stages
per wheel
Thermal protection: only thermal fuse
Weight
620 g (22.0 oz)
Sound pressure level:< 70 dB (A)
Vibration:
< 2.5 m/s
HGE 23-650 LCD
Output:
2100 W (max 2300 W)
Stage 2: .................... 500 °C
2
stage 1: ......................80 °C
2
Air temperature:
Stage 1: ......................80 °C
Stage 2: ...............80-650 °C
Blower:
steplessly adjustable
Air volume:
stage 1: ........... 150-250 l/min
Stage 2: ........... 150-500 l/min
Programs:
1=250°C /
min
2=350°C /
min
3=450°C /
min
4=550°C /
min
Temperature display:LCD in 10 °C steps
Thermal protection: yes
Weight
700 g (24.2 oz)
Sound pressure level:< 70 dB (A)
Vibration:
< 2.5 m/s
HGS 22-630
Output:
2100 W (max 2200 W)
Air temperature:
Stage 2: ...............80-630 °C
Air volume:
stage 0: ...........................off
Stage 1: ......... 150-300 l/min
Stage 2: ......... 300-500 l/min
Temperature
Setting:
stepless in 9 stages
per wheel
Thermal protection: only thermal fuse
Weight
650 g (23.0 oz)
Sound pressure level:< 70 dB (A)
Vibration:
< 2.5 m/s
Changes due to technological progress reserved.
Values measured as per EN 60745.
Machine in protection class II
The technical specifications quoted are subject to
tolerances (in compliance with relevant valid
standards).
ENGLISH en
approx.350 l/
approx.400 l/
approx. 500 l/
approx. 400 l/
2
stage 1: ...............80-630 °C
2
11

Advertisement

loading

This manual is also suitable for:

Hg 20-600Hge 23-650 lcdHgs 22-630