Download Print this page

Maintenance; Troubleshooting - Metabo HG 16-500 Original Instructions Manual

Hide thumbs Also See for HG 16-500:

Advertisement

en
ENGLISH
At stage 1 of the sliding switch (4) the temperature
is always 80 °C (cold-air stage). Use the cold-air
stage to dry paint, cool workpieces or to cool down
the nozzle before changing an accessory part.
At stage 2 and 3 of the sliding switch (4), the
temperature can be set steplessly at the adjusting
wheel (6).
The numbers 1 - 9 shown on the adjusting wheel are
used for orientation. "1" means 80 °C."9" means
600 °C (maximum temperature).
6.3
HGE 23-650 LCD
The sliding switch (4) can be used to switch the tool
on and for selecting between 2 stages.
At stage 1 of the sliding switch (4) the temperature
is always 80 °C (cold-air stage). Use the cold-air
stage to dry paint, cool workpieces or to cool down
the nozzle before changing an accessory part.
At stage 2 of the sliding switch (4) the temperature
can be set steplessly.
Setting temperature:
Briefly pressing the joystick (10) to the left/right
increases or lowers the set value in 10 ° steps.
Longer pressing of the joystick (10) changes the
value faster.
Note:
If the desired temperature is set, the blower
(depending on the selected speed/air volume)
needs a few seconds to reach the set value. The
"°C" symbol flash during this period.
When the hot-air blower is switched off, the last
value set is retained.
Setting air volume:
Pressing the (8)
the joystick (10) to the left/right sets the air volume
or fan speed.
Program operation:
Four programs for the most frequent types of work
are set in the factory. Press the "P" button for
program operation. The display shows
program 1. Pressing the program button again,
takes you to the programs
button again to return to normal operation.
Program 1: Forming plastic pipes
Program 2: Welding plastic pipes
Program 3: Removing paint
Program 4: Soft soldering
(technical data see chapter 12.)
Changing programs and saving:
The values in the four programs can be changed
and saved. To do this, first press the "P" program
button until the program to be changed is displayed.
Set the desired air volume and temperature. Press
the "P" program button for saving until the
disappears from the display (about 2 seconds). The
entered values are now saved in the program.
Note:
- To return from program operation to the normal
function, press the program button (9) until the
program symbol in the display (7) has
disappeared.
10
button and then briefly pressing
,
and
. Press the
- The factory settings of the programs are listed in
chapter 12.
6.4
HGS 22-630
The sliding switch (4) can be used to switch the tool
on and for selecting between 2 stages.
The air volume varies in the 2 stages
(stage 1: 150-300 l/min, stage 2: 300-500 l/min).
At stage 1 and 2 of the sliding switch (4), the
temperature can be set steplessly at the adjusting
wheel (6).
The numbers 1 - 9 shown on the adjusting wheel are
used for orientation. "1" means 80 °C."9" means
630 °C (maximum temperature).
6.5
Stationary operation
If you wish to use the hot-air blower as a
stationary tool, ensure that it is placed on a
safe, anti-slip and clean base.
To use the hot air gun in stationary operation, place
it on the anti-slip bases (5).

7. Maintenance

The air inlet (3) must be free from foreign bodies.
Clean the air inlet (3) gif necessary.
For the HGS 22-630 remove the fine dust filter (3)
for cleaning (see fig., page 2). Replace worn fine
dust filters. Replacement filter set: order no.
344199400.

8. Troubleshooting

Thermal protection in the event of heat
accumulation (only for HGE 23-650 LCD):
A thermal switch switches off the heater in case of
excessive interference in the air outlet of the blow-
out opening (heat accumulation). However, the
blower continues running. When the blow-out
opening is free again, the heater cuts in again
automatically after a short while. The thermal switch
for
can also trip after the tool is switched off. In this
case, after the tool is switched on again it takes
longer than usual until the temperature at the blow-
out opening is reached.
Thermal fuse in the event of overload (for all
devices):
The thermal fuse switches the tool off completely in
the event of overloading. See chap. repairs!
9. Accessories
Use only genuine Metabo accessories.
If you need any accessories, check with your
symbol
dealer.
For a complete range of accessories, see
www.metabo.com or the catalogue.

Advertisement

loading

This manual is also suitable for:

Hg 20-600Hge 23-650 lcdHgs 22-630