Toyotomi Toyostove Laser 300 Installation And Operation Instruction Manual page 28

Laser clean heating system/vented heater
Hide thumbs Also See for Toyostove Laser 300:
Table of Contents

Advertisement

Laser 300_Type A_US.qxd 15.3.26 16:12 ページ 28
5.
Install the inner flue pipe.
a.
For wall thickness 5-
From inside the room, insert the inner flue pipe through the hole. Make sure the arrow on the inner flue
pipe is pointing up. Secure the inner flue pipe to the wall with the three wood screws.
(See Fig. 7.)
b.
For wall thickness 4" to 5-
In the event that the wall is too thin, use the spacer as indicated in Fig. 8.
c.
From outside, insert the outer flue pipe through the hole. Secure the outer flue pipe to the wall by turning it
clockwise. This locks the two halves together (See fig. 9).
IMPORTANT:
Inner flue pipe
28
3
/
" to 9"
16
Inner flue pipe
Arrow
Wood screws
3
/
"
16
Inner flue pipe
Arrow
Tapping screws
Wood screws
Make sure the arrow on the outer flue pipe flange is pointing up.
Make sure to secure the outer flue pipe well. (A-part shown in Fig. 9)
Check inside flue pipe for insulation and remore if any.
Outer flue pipe
Inside
2˚ downward Min.
Fig. 7
Spacer
2˚ downward Min.
Spacer
Fig. 8
Inside
2˚ downward Min.
Outer flue pipe
Fig. 9
Outside
5-
3
/
" to 9"
16
Inside
Outside
3
4" to 5-
/
"
16
Outside
A
Arrow
Outer flue pipe flange

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents