Download Print this page

Master 17 Technical Data Manual page 8

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 6
►2.16.In any condition of use or appliance
en
standstill, make sure that the flexible gas
it
hose is not damaged (crushed, bent,
twisted, taught).
de
►2.17.If the smell of gas is perceived,
es
switch the appliance off immediately,
fr
close the gas cylinder, disconnect the
mains plug and then contact the after-
nl
sales assistance.
pt
►2.18.If the gas hose must be replaced,
only use the flexible type suitable for
da
the pressure used, referring to national
fi
regulations. The gas hose must measure
no
1,5 m.
►2.19.When the appliance is controlled
sv
by a room thermostat (optional article),
pl
the generator can switch back on at any
ru
time i.e. when the temperature drops
below the threshold set.
cs
►2.20.When it is not used, disconnect
hu
the generator from the network plug,
close the gas supply, disconnect the gas
sl
hose from the generator and plug the gas
tr
inlet on the generator.
hr
►2.21.Have the after-sales assistance
check correct functioning of the generator
lt
at least once a year and/or according to
lv
need.
et
►►3. TYPE OF FUEL
ro
Use category I
3
sk
►►4. CONNECTION AND
bg
REPLACEMENT OF THE GAS
uk
CYLINDER
The gas cylinder must be replaced in the
bs
open air, away from heat sources, in an
el
atmosphere without flames.
zh
Only the following accessories must be
used for connection of the gas cylinder to
the generator:
•Liquid gas flexible pipe.
•Liquid gas pressure regulator complete
with safety valve.
B/P gas only.
CHECK THE INTEGRITY OF THE GAS
SUPPLY PIPE. IF THE GAS HOSE
MUST BE REPLACED, ONLY USE THE
FLEXIBLE TYPE SUITABLE FOR THE
PRESSURE USED, REFERRING TO
NATIONAL REGULATIONS.
►To connect the generator to the gas
cylinder:
ATTENTION:
ALL
SINISTRAL, I.E. THEY ARE TIGHTENED
IN AN ANTI-CLOCKWISE DIRECTION.
►4.1.Screw the gas hose to the generator
fitting (Fig. 4).
►4.2.Install the pressure regulator on the
gas cylinder. Make sure there is a gasket
present on the regulator (if envisioned by
the type of connection) (Fig. 5).
►4.3.Connect the gas hose to the
pressure regulator (Fig. 6).
►4.4.Open the gas cylinder cock (Fig.
7).
►4.5.Press
the
button (Fig. 8). Check tightness of
fittings using soapy water: bubbles
indicate a gas leak (Fig. 9). Several
gas cylinders can be fitted together to
obtain greater autonomy. The use of
30 kg gas cylinders is recommended,
up to heating capacity of 33 kW. Over
the power of 33 kW use gas cylinders
with greater capacity. The use of gas
cylinders with suitable capacity is
recommended in order to prevent
problems due to lack of gasification of
the fuel. The correct functioning pressure
(see data plate applied to the generator)
is given by the regulator supplied or an
equivalent model.
THREADING
IS
regulator
release

Advertisement

loading

This manual is also suitable for:

33m53m73m