Download Print this page

Master 17 Technical Data Manual page 10

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 6
►►8. HEAT CAPACITY
en
REGULATION
it
Depending on the type of generator, the
appliance heat capacity can be regulated.
de
The heat capacity can be regulated by
es
acting on the knob positioned on the
fr
base of the generator (Fig. 22) or on
the pressure regulator installed on the
nl
gas cylinder (Fig. 23), depending on the
pt
model.
da
►►9. SWITCH-OFF FOR MANUAL
fi
MODELS (... / ...M / ...DV)
no
►9.1.Close the gas cylinder (Fig. 24).
►9.2.Leave the fan to cool for about 60
sv
s, in order to prevent internal damage
pl
due to overheating (generator internal
cooling).
ru
►9.3.Take the "O/I" switch to position "O"
cs
(Fig. 25).
hu
►9.4.Disconnect the generator from the
mains electricity (Fig. 26).
sl
►9.5.Disconnect the generator from the
tr
gas supply pipe (Fig. 27-28-29).
hr
►►10. SWITCH-OFF FOR
lt
ELECTRONIC MODELS (...E)
lv
►10.1.Take the "O/I" switch to position
"O" (Fig. 25). The flame goes out and the
et
generator performs the post-ventilation
ro
phase. Wait for the cycle to be completed
sk
in order to prevent internal damage due
to overheating (the phase is automatic
bg
and can last 50 s÷5 min depending on
uk
the internal/external temperature at the
generator).
bs
►10.2.Close the gas cylinder (Fig. 24).
el
►10.3.Disconnect the generator from
zh
the mains electricity (Fig. 26).
►10.4.Disconnect the generator from
the gas supply pipe (Fig. 27-28-29).
N.B.: Do not disconnect the generator
from the mains electricity, before the
end of the post-ventilation phase, in
order to prevent internal damage due
to over-heating.
►►11. CLEANING AND
MAINTENANCE
Have the after-sales assistance check
correct functioning of the generator at
least once a year and/or as required. The
appliance must be cleaned before it is
put away after use.
starting
►11.1.Before
maintenance, care and repairs of the
appliance,
carry
sequence [Par. 9. "SWITCH-OFF FOR
MANUAL MODELS (... / ...M / ...DV)" or
"10. SWITCH-OFF FOR ELECTRONIC
MODELS (...E)"].
►11.2.Cleaning only concerns the air
vent (rear side) of the generator.
►11.3.When the appliance is used
again, check the state of integrity of the
gas hose and power supply cable. If in
doubt regarding their integrity, request
the assistance of the technical after-sales
service.
►11.4.Do not carry out unauthorised
interventions.
►►12. ROOM THERMOSTAT
CONNECTION (...E) (optional)
Remove the plug connected to the
appliance
and
thermostat (optional) (Fig. 30).
See wiring diagram (...E).
any
type
out
the
switch-off
connect
the
room
of

Advertisement