replacement of a damaged power
supply cable) must be performed by
the manufacturer, by its technical after-
sales service, by a person with similar
qualification, in a way to prevent all
risks, even if disconnection from the
mains power supply is envisioned.
►2.1.For correct use of the generator
and for preservation of the fuel, follow
all local regulations and the Standard in
force.
►2.2.The generator requires suitable
fresh air in order to function. It is therefore
used outdoors or in rooms with assured
and continuous supply of fresh air. Good
airing is supplied when the volume of the
room is calculated on the heat capacity,
using the formula of 1 m³ every 100 W
of power. In no case the recommended
volume of the room must be smaller than
100 m³. Good ventilation is guaranteed
by an opening that satisfies the formula
stating 25 cm² per kW of heat power, with
minimum of 250 cm², equally divided
between the upper and lower part of
the room. National Standards in force
are valid for installation, including the
Technical Standards and the provisions
regarding accident-prevention and the
prevention of fires.
►2.3.The appliance must only be used
as a hot air generator (heating mode)
or fan (ventilation mode, for models that
envision this functionality). Follow these
instructions scrupulously.
►2.4.The Manufacturer declines all
liability for damage/injury to objects/
persons deriving from improper use of
the appliance.
►2.5.Only power the generator using the
type of fuel expressly specified and with
current having the voltage and frequency
indicated on the data plate applied to the
generator.
►2.6.Make sure the generator is only
connected to suitable electric networks
with differential switch and suitable earth.
►2.7.Only use extensions with suitable
section, appropriately connected to earth.
►2.8.The generator must function on a
stable level and fire-proof surface, in a
way to prevent the risk of fire.
►2.9.It is prohibited to use the appliance
in basements and rooms below ground
level.
►2.10.The generator must not be used
in places where explosive dusts, fumes,
gases, fuels, solvents and paints are
present.
►2.11.Whenever the generator is used in
proximity of tarpaulin, awnings or similar
covering materials, it is considered to use
additional fire-proof protections. Make
sure the hot parts of the generator are kept
at a suitable distance from inflammable
materials (material, paper, wood, etc.)
or thermolabile materials (including the
power supply cable), which in no case is
less than 2,5 m.
►2.12.Position the gas cylinder in a
protected position, behind the appliance
(Fig. 1). The generator must never face
the gas cylinder (Fig. 2).
►2.13.The air vent (rear side) and/or the
air outlet vent (front side) cannot be totally
or partially obstructed for any reason
(Fig. 3). Do not use any air ducting from
or to the generator. Make sure air intake
slots, present on the bottom of the base,
are not obstructed (for models using this
solution).
►2.14.If
the
generator
switch on or switch-on is anomalous,
consult the relative section (Par. 13.
"TROUBLESHOOTING").
►2.15.The generator must never be
moved, handled or subjected to any
maintenance interventions when it is
running.
en
it
de
es
fr
nl
pt
da
fi
no
sv
pl
ru
cs
hu
sl
tr
hr
lt
lv
et
ro
sk
bg
uk
bs
el
does
not
zh

Advertisement

loading

This manual is also suitable for:

33m53m73m