Samsung AR JV5N Series User & Installation Manual page 45

Table of Contents

Advertisement

Installing and connecting the drain hose of the indoor unit
5cm
less
Keep a clearance of at least
5 cm between the end of the
drain hose and the ground.
1) Correct connection
Drain hose
• D on't tie drain hose to the assembly pipe which may lead to water leakage.
• If the diameter of the connection hose is smaller than the product's drain hose, water leakage may occur.
Drain hose installation
1. If necessary, connect the 2 meter extension drain hose to the drain hose.
2. If you use the extension drain hose, insulate the inside of the extension drain hose with a shield.
3. Fit the drain hose into 1 of 2 drain hose holes, then fix the end of the drain hose tightly with a clamp.
• I f you do not use the other drain hose hole,
block it with a rubber stopper.
4. When extending the Drain Hose, hold the end of Drain Hose and Extended Hose,
rotate and insert the drain hose into Extended hose for 40~45 mm. Make sure
the two hoses are firmly connected to ensure that there is no water leakage.
5. Connect the Drain Hose after using Foam Insulation to wrap the Extended Hose. Then, Use vinyl tape to wrap each
side of the connection by 20 mm .
Drain hose
Extension
drain hose
NA_GOOD_A3050_IB&IM_EN_DB68-05202A-02.indd 45
Ditch
Do not place the end of the
drain hose in a hollow.
Pipe
40~45 mm
Drain hose
English-45
2) Incorrect connection
Drain hose
20 mm
or more
Extension
drain hose
Vinyl Tape
After completing the
installation of the drain
hose, pour water into
the drain pan to check
whether the hose is well
drained.
Pipe
Drain hose hole
20 mm
or more
Foam Insulation