Installing and connecting the device
3.2 Installing the device
3.2.2

Installation on a DIN rail

3.2.2.1

Attaching the DIN rail bracket

Before you can install the device on a DIN rail, you will need to attach the DIN rail clip to the
device.
The fasteners and screws required are supplied with the device for the selected mounting
option (as specified in order number).
Requirement
• 1 DIN rail clip
• 4 screws
• 1 T20 screwdriver
Procedure
1. Fasten the DIN rail clip with four screws.
3.2.2.2

Mounting on DIN rails

Requirement
• DIN rail, 35 mm standard profile
The DIN rail is installed at the installation site.
Note
Ensure that the wall or ceiling can hold four times the total weight of the device including
DIN profile rail and additional expansion cards. See Mounting instructions (Page 26).