Remote Control Display During The Operation Stop; Outline Of Heating Or Cooling Operation - Mitsubishi Heavy Industries SRK100VNXPZSX Technical Manual

Table of Contents

Advertisement

(vii) Combination of patterns which can be set for the timer operations
Sleep time
Set OFF timer by hour
Set ON timer by hour
Set OFF timer by clock
Set ON timer by clock
Weekly timer
Note (1)
: Allowed
(b) RC-E5
(i)
Sleep timer
Set the duration of time from the present to the time to turn off the air-conditioner.
It can be selected from 10 steps in the range from "OFF 1 hour later" to "OFF 10 hours later". After the sleep timer
setting, the remaining time is displayed with progress of time in the unit of hour.
(ii)
OFF timer
Time to turn OFF the air-conditioner can be set in the unit of 10 minutes.
(iii)
ON timer
Time to turn ON the air-conditioner can be set. Indoor temperature can be set simultaneously.
(iv)
Weekly timer
Timer operation (ON timer, OFF timer) can be set up to 4 times a day for each weekday.
(v)
Timer operations which can be set in combination
Item
Item
Timer
OFF timer
ON timer
Weekly timer
Note (1)
: Allowed
(2) Since the ON timer, sleep timer and OFF timer are set in parallel, when the times to turn ON and OFF the air-conditioner are duplicated, the
setting of the OFF timer has priority.
(5)

Remote control display during the operation stop

When the operation is stopped (the power source is turned ON), it displays preferentially the "Room temperature", "Center/
Remote", "Filter sign", "Inspection" and "Timer operation".
(6)

Outline of heating or cooling operation

(a)
Operation of major functional components in heating mode
Compressor
Indoor fan
Outdoor fan
4-way valve
(b) Operation of major functional components in Cooling mode
Compressor
Indoor fan
Outdoor fan
4-way valve
Sleep time
Set OFF timer by hour
: Not
Timer
OFF timer
: Not
Thermostat ON
ON
ON
ON
ON
Thermostat ON
ON
ON
ON
OFF
Set ON timer by hour Set OFF timer by clock Set ON timer by clock
ON timer
Heating
Thermostat OFF
OFF
ON(HOT KEEP)
OFF
(few minutes ON)
ON
Cooling
Thermostat OFF
OFF
ON
OFF
(few minutes ON)
OFF
68
-
-
'17 • PAC-T-257
Weekly timer
Weekly timer
Failure
OFF
OFF
OFF
OFF
(3 minutes ON)
Failure
OFF
OFF
OFF
(few minutes ON)
OFF