Rangemaster Excel FSD Users Manual & Installation page 35

110 dual fuel users guide & installation & service instructions
Table of Contents

Advertisement

WARNING  SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
Pressure Testing
Connect the appliance to the gas supply. Check the
appliance is gas sound.
The gas pressure can be measured at one of the left
hand hotplate burner jets. Lift off a burner head. Fit the
pressure gauge to the jet. Turn on the hotplate burner
and turn on and light one of the other burners.
The pressure should be 29mbar for Butane and 37mbar
for Propane. After checking the pressure, turn the taps
off and replace the burner head.
Reassemble burner top, making sure it is reassembled in
the correct way on the burner body.
Check the appliance is gas sound.
Check operation of all the burners.
Hotplate
Right hand Wok burner
Large Burners
Medium Burners
Small Burner
Natural Gas
Injector
Bypass screw Injector
internal 80
96
external 129
134
54
109
39
75
38
35
L.P. Gas
Bypass screw
internal 54
57
external 77
87
40
68
32
51
28

Advertisement