Input Voltage Reconnect Procedure; Output Connections; Wire Feeder Output Connections - Lincoln Electric Invertec STT II Operator's Manual

Lincoln electric invertec stt ii advanced process welder
Hide thumbs Also See for Invertec STT II:
Table of Contents

Advertisement

A-4
INPUT VOLTAGE RECONNECT
PROCEDURE
As shipped from the factory, multiple voltage
(208/230/460 VAC) or (200/220/380 - 415/440 VAC)
machines are internally configured for the highest
input voltage (440 or 460 VAC).
1. For Connections to 440 or 460 VAC verify the inter-
nal configurations to the procedures shown below and
refer to Figure A.2.
2. For Connections to 200,208,220,230,380 or 415
VAC follow the procedure shown below and refer to
figure A.2.
NOTE: Turn main power to the machine OFF
before performing the reconnect procedure.
Failure to do so will result in damage to the
machine. DO NOT switch the reconnect bar with
machine power ON.
To Operate at
460 or 440 VAC
1. Open reconnect panel
2. Move input voltage switch
3. Move lead "A" to 440-460
INSTALLATION
FIGURE A.2 RECONNECT PANEL
Procedure
access door on wrap-around.
to Voltage = 380 -460V pos-
ition.
Terminal.
INVERTEC STT II
380 or 415 VAC
1. Open reconnect panel
2. Move input voltage switch
3. Move lead "A" to 380-415
220 or 230 VAC
1. Open reconnect panel
2. Move input voltage switch
3. Move lead "A" to 220-230
200 or 208 VAC
1. Open reconnect panel
2. Move input voltage switch
3. Move lead "A" to 200-208

OUTPUT CONNECTIONS

WIRE FEEDER OUTPUT CONNECTIONS

Refer to the Accessories section of this manual for
instructions on connecting a wire feeder to the
Invertec STT II.
The LN-742 or STT-10 wire feeder is the recommend-
ed feeder for use with the Invertec STT II.
4A
access door on wrap-around.
to Voltage = 380 -460V
position.
Terminal.
access door on wrap-around.
to Voltage = 200 -230V
position.
Terminal.
access door on wrap-around.
to Voltage = 200 -230V
position.
Terminal.