4.9 DME Tuning and ADF

4.9.1 DME Tuning Function
The GIA 63(W) can channel a DME based on the tuned VLOC frequency. The GIA 63(W) outputs 2 of
5, BCD or Slip parallel DME and King Serial DME channeling format. When DME COMMON is held
low, the GIA 63(W) actively tunes the DME.
4.9.2 DME Interface and ADF Electrical Characteristics
4.9.2.1 Parallel DME Tuning
Pin Name
PARALLEL DME 1 MHZ-D
PARALLEL DME 100 KHZ-A
PARALLEL DME 100 KHZ-B
PARALLEL DME 100 KHZ-C
PARALLEL DME 100 KHZ-D
PARALLEL DME 50 KHZ
PARALLEL DME 1 MHZ-A
PARALLEL DME 1 MHZ-B
PARALLEL DME 1 MHZ-C
PARALLEL DME 100KHZ-E
PARALLEL DME 1MHZ-E
NAV DME COMMON
For each of the parallel DME tuning discrete outputs:
INACTIVE: Floating (can be pulled up to externally sourced Vout in the range 0 ≤  V out ≤  3 3VDC)
Leakage current in the INACTIVE state is typically ≤ 10 uA to ground
ACTIVE: Vout ≤ 0.5VDC with ≤  2 0 mA sink current
Sink current must be externally limited to 20 mA max
NAV DME COMMON must be pulled low to indicate to the NAV module that it is the device channeling
the DME.
INACTIVE: 10 ≤  V in ≤  3 3VDC or Rin ≥ 100kΩ
ACTIVE: Vin ≤ 1.9VDC with ≥  7 5 uA sink current, or Rin ≤ 375Ω
Sink current is internally limited to 200 uA max for a grounded input
Page 4-24
Revision S
Connector
Pin
P602
33
P602
37
P602
39
P602
40
P602
42
P602
43
P602
45
P602
46
P602
47
P602
54
P602
56
P602
41
GIA 63/GIA 63W Installation Manual
I/O
Out
Out
Out
Out
Out
Out
Out
Out
Out
Out
Out
In
190-00303-05

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gia 63

Table of Contents