Part 2 - Maintenance; Service Technician; Owner Maintenance - Westinghouse WBRC 199W Series User's Information Manual

Gas fired residential combi boiler
Table of Contents

Advertisement

Hydronic systems that use glycol as heat transfer fluid must be serviced periodically. Glycol can break down over time, become acidic,
and attack gaskets and seals in appliances. This can result in property damage, severe personal injury, or death.
Each glycol manufacturer has different recommendations for testing and replacement. Do not test glycol quality yourself. Have your
qualified service technician check glycol quality during annual servicing. If you are unsure when your glycol was last tested, call a
qualified service technician to test and replace glycol, if necessary.
If the appliance is not to be used for an extended period of time during freezing conditions, consider shutting down the system and
draining it of water. Shut off the gas and cold water supply valves.
DO NOT attempt to disassemble this appliance. Doing so could result in improper appliance operation or premature appliance failure,
substantial property damage, and/or severe personal injury or death due to electric shock, fire, or explosion. If repairs are required,
contact a qualified service technician.
DO NOT touch the exhaust vent pipe. Doing so could result in substantial personal injury.
Be careful when opening a hot water faucet or draining
water from the appliance. Water temperature over 125
can instantly cause severe burns, or death, from scalds.
Children, disabled, and elderly are at the highest risk of
being scalded. See instruction manual before setting
temperature at appliance. Feel water before bathing or
showering!
PART 2 – MAINTENANCE
A. SERVICE TECHNICIAN
The following maintenance should be performed by a qualified service technician annually:
General
Attend to any reported problems.
Inspect the interior of the appliance cabinet area; clean and vacuum if necessary.
Clean the condensate trap and fill with fresh water.
If applicable, check the condensate neutralizer and ensure it is full of condensate neutralizing marble chips.
Check for leaks: Water, gas, flue and condensate.
Verify exhaust vent and intake piping are in good condition and sealed tight.
Check exhaust vent and intake pipe bracing. Ensure bracing is undamaged and in good condition.
Check appliance water pressure, piping and expansion tank.
Check control settings.
Check ignition electrode. Sand off any white oxide. Clean and reposition.
Check ignition and ground wiring.
Check all control wiring and connections.
Check burner flame pattern (stable and uniform).
Additional Items if Combustion or Performance is Poor
Clean heat exchanger and flue ways.
Remove burner assembly and clean burner head using compressed air only.
Once the maintenance items are completed, the service technician should review service with the owner.
B. OWNER MAINTENANCE
Periodically
Check area around the appliance.
APPROXIMATE TIME / TEMPERATURE RELATIONSHIPS IN SCALDS
120
o
F
125
130
135
140
145
150
155
o
F
o
F
o
F
o
F
o
F
o
F
o
F
o
F
WHL-013 REV. 1.22.16
7
More than 5 minutes
1 ½ to 2 minutes
About 30 seconds
About 10 seconds
Less than 5 seconds
Less than 3 seconds
About 1 ½ seconds
About 1 second

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wbrc 140w seriesWbrc 140f seriesWbrc 199f series

Table of Contents