Bryant 800SB Operating Instructions Manual page 45

80% afue, single stage, multi-speed ecm, 4-way multipoise, non–condensing gas furnace
Table of Contents

Advertisement

800SB/801SB: Installation, Start–Up, Operating and Service and Maintenance Instructions
Installation Date: ____________________________
Furnace
Thermostat
Humidifier
Indoor Coil
Outdoor Unit
Furnace Location_____________________________
Furnace Orientation:
Gas Adjustment
LOCAL GAS HEAT CONTENT_____________(btu/cu. ft.)
(contact your local gas utility-not required for propane)
INLET SUPPLY PRESSURE**
MANIFOLD PRESSURE: High fire___________ in.
**Supply pressure should be checked with furnace and all other gas appliances running
FIRING RATE:
Firing rate = heat content (btu/cu. ft.) X size of the dial (cu. ft/rev) X # of rev. per 60 sec (rev/sec) X 3600 (sec/hr)
Example- (1050 btu/cu. ft.) X (0.5 cu. f t ./rev.) X (2 revs./60sec) X (3600 sec/hr)= 63,000 btu/hr
OR use the "Gas Rate" chart in the startup and adjustment section of the installation manual
HIGH HEAT_________________ btu/hr
LEAVING AIR TEMPERATURE
RETURN AIR TEMPERATURE
TEMPERATURE RISE
Temperature rise is equal to the supply air temp minus the return air temp @ steady state operation.
The supply temperature should be measured away from the line of sight of the Heat Exchanger
+90 % VENTING SYSTEM
Pipe Dia_____________ # of Elbows_____________ Total Length _____________
Termination Type:
Termination Locat i on:
MID-EFFICIENCY VENTING SYSTEM
METAL:
(circle one)
Vent Dia________Total Ht.________
Connector Type:
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
GAS FURNACE CHECKLIST
Model
____Upflow
Downflow
______________ in.
(CLOCKED METER FOR NAT. GAS – assure only furnace is running)
__________(F) high
__________(F) high
__________(F) high
Concentric
(circle one)
Roof
(circle one)
B vent
Vent Conn. Dia_______ Conn. Length ______
ft.
Single Wall
B Vent
Fig. 52 – Gas Furnace Checklist
Equipment
Installed altitude __________________
Horizontal Right
SPECIFIC GRAVITY________/cu. ft.
ORIFICE #_____________
W.C.
Low fire_____________ in.
W.C.
LOW HEAT
______________________________
_________ (F) low
_________ (F) low
_________ (F) low
2 pipe (std)
Sidewall
Chimney Liner
Connector Rise Above Furnace _________
45
Serial #
Horizontal Left
W.C.
btu/hr
ft.
# of Elbows________
ft.
ft.
A220915