Table 15 – Gas Rate (Cu Ft./Hr.)
SIZE OF TEST
SECONDS
DIAL
FOR 1
1 Cu
2 Cu
5 Cu
REVOLUTION
Ft.
Ft.
Ft.
10
360
720 1800
11
327
655 1636
12
300
600 1500
13
277
555 1385
14
257
514 1286
15
240
480 1200
16
225
450 1125
17
212
424 1059
18
200
400 1000
19
189
379
947
20
180
360
900
21
171
343
857
22
164
327
818
23
157
313
783
24
150
300
750
25
144
288
720
26
138
277
692
27
133
267
667
28
129
257
643
29
124
248
621
30
120
240
600
31
116
232
581
32
113
225
563
33
109
218
545
34
106
212
529
35
103
206
514
36
100
200
500
37
97
195
486
38
95
189
474
39
92
185
462
40
90
180
450
41
88
176
439
42
86
172
429
43
84
167
419
44
82
164
409
45
80
160
400
46
78
157
391
47
76
153
383
48
75
150
375
49
73
147
367
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
SIZE OF TEST
SECONDS
DIAL
FOR 1
1 Cu
2 Cu
5 Cu
REVOLUTION
Ft.
Ft.
50
72
144
360
51
71
141
355
52
69
138
346
53
68
136
340
54
67
133
333
55
65
131
327
56
64
129
321
57
63
126
316
58
62
124
310
59
61
122
305
60
60
120
300
62
58
116
290
64
56
112
281
66
54
109
273
68
53
106
265
70
51
103
257
72
50
100
250
74
48
97
243
76
47
95
237
78
46
92
231
80
45
90
225
82
44
88
220
84
43
86
214
86
42
84
209
88
41
82
205
90
40
80
200
92
39
78
196
94
38
76
192
96
38
75
188
98
37
74
184
100
36
72
180
102
35
71
178
104
35
69
173
106
34
68
170
108
33
67
167
110
33
65
164
112
32
64
161
116
31
62
155
120
30
60
150
Table 16 – Orifice Size* and Manifold Pressure (in. w.c.) for Gas