Gamma correction
10.8
The gamma correction is changeable.
GenICam Parameters
Gamma
ROI (Region of Interest)
10.9
The specified region of image can be output from camera with ROI function.
GenICam Paramters
Width
Height
OffsetX
OffsetY
The ROI region settings are below:
STC-MBS881POE / STC-MCS881POE
Product Specifications and User's Guide
IFloat Type
Gamma correction
Range: 0 to 4.0
Default: 1.0
IInteger Type
Width (horizontal size) of output image (in pixel)
Range: 264 to 4,096
Default: 4,096
Adjustable steps: 8
("Width" + "OffsetX") should not exceeded maximum width.
IInteger Type
Height (vertical size) of output image (in line)
Range: 4 to 2,160
Default: 2,160
Adjustable steps: 4
("Height" + "OffsetY") should not exceeded maximum height.
IInteger Type
Horizontal offset for output image (in pixel)
Range: 0 to 3,832
Default: 0
Adjustable steps: 8
IInteger Type
Vertical offset for output image (in line)
Range: 0 to 2,156
Default: 0
Adjustable steps: 4
ROI region
OffsetX
Width
OffsetY
Height
No.19S208-00
47/73