Troubleshooting - Central Pneumatic Professional Laser Series Set Up And Operating Instructions Manual

In-line air shear
Table of Contents

Advertisement

If the Laser Light ceases to function, check the batteries.
problem
Decreased output.
1.
2.
3.
4.
5.
6.
7.
Housing heats
1.
during use.
2.
Severe air
1.
leakage.
(Slight air leakage
is normal,
2.
especially on
older tools.)
3.
4.
Laser does not
1.
light.
2.
3.
Follow all safety precautions whenever diagnosing or servicing the
tool. disconnect air supply before service.
SKU 65706

troubleshooting

possible causes
Not enough air pressure and/
or air flow.
Obstructed trigger.
Incorrect lubrication or not
enough lubrication.
Blocked air inlet screen (if
equipped).
Air leaking from loose
housing.
Mechanism contaminated.
Vane wear or damage.
Incorrect lubrication or not
enough lubrication.
Worn parts.
Cross-threaded housing
components.
Loose housing.
Damaged valve or housing.
Dirty, worn or damaged valve.
Batteries are worn.
Laser electrical contacts are
dirty.
Laser Module (37) is
damaged.
For technical questions, please call 1-800-444-3353.
Likely solutions
1.
Check for loose connections and make sure
that air supply is providing enough air flow
(CFM) at required pressure (PSI) to the
tool's air inlet. do not exceed maximum air
pressure.
2.
clean around trigger to ensure free
movement.
3.
Lubricate using air tool oil and grease
according to directions.
4.
Clean air inlet screen of buildup.
5.
Make sure housing is properly assembled
and tight.
6.
Have qualified technician clean and lubricate
mechanism. Install in-line filter in air supply
as stated in Initial Set Up: Air Supply.
7.
Replace all vanes.
1.
Lubricate using air tool oil and grease
according to directions.
2.
Have qualified technician inspect internal
mechanism and replace parts as needed.
1.
Check for incorrect alignment and uneven
gaps. If cross-threaded, disassemble and
replace damaged parts before use.
2.
Tighten housing assembly. If housing cannot
tighten properly, internal parts may be
misaligned.
3.
Replace damaged components.
4.
Clean or replace valve assembly.
1.
Replace batteries.
2.
Clean Laser Module (37) and ON / OFF
Switch (40) contacts.
3.
Replace Laser Module (37).
Page 12

Advertisement

Table of Contents
loading

This manual is also suitable for:

65706

Table of Contents