Listing Information - Travis Industries Lopi 1250 Republic Owner's Manual

Wood insert
Table of Contents

Advertisement

Listing Label
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT INSTALLATION AND RESTRICTIONS IN YOUR AREA.
Report No. B0515PRT-001
Control No. 4000515
MANTEL
D
A
INSERT
F
E
HEARTH
Factory-Built (Z.C.) Fireplace installations require a minimum 24" starter section directly connected to the fireplace chimney or a full re-line.
Factory-Built (Z.C.) Fireplace chimney must have a minimum cross-sectional area of 28.85 square inches. The Factory-Built (Z.C.) Fireplace
damper and control must be removed, or secured in the open position. For minimum Factory-Built (Z.C.) Fireplace firebox size, see manufacturer's
installation instructions. Factory-Built (Z.C.) Fireplace floor protection must be 3/8" minimum non-combustible material or equivalent, extending
16" in front of insert and 8" to both sides. A metal deflector plate must be installed if the flue collar is not completely behind the Lintel plate of the
Factory-Built (Z.C.) Fireplace openings.
PREVENT HOUSE FIRES - Install and use only in accordance with the manufacturer's installation and operating instructions. Contact your local
building or fire officials about restrictions and installation inspection in your area. Do not connect this unit to a chimney flue serving another
appliance.
Electrical Rating:
115V., 60 Hz, 1.8 Amps
Optional Blower:
# 99000128
Do not route power cord under or in front of appliance.
Replace glass only with 5mm neoceramic or
ceramic glass.
Certified to comply with 2015 particulate emission standards. Not approved for sale after May 15, 2020. 4.4 g/h, Method 28, 5H, 2015
2015
Made in U.S.A.
© Travis Industries

Listing Information

DO NOT REMOVE THIS LABEL
SUITABLE FOR USE IN FACTORY-BUILT (Z.C.) FIREPLACES AND MASONRY FIREPLACES.
CONFORMS TO UL STD 1482 and CERTIFIED TO ULC STD S628-93
FACTORY-BUILT (Z.C.) FIREPLACE OR MASONRY FIREPLACE INSTALLATION
C
B
NON-COMBUSTIBLE
EXTENSION
FIREPLACE FACING
U.S. ENVIRONMENTAL PROTECTION AGENCY
2016
2017
2018
Jan
Feb
MODEL:
1250 INSERT
Certified for USA and Canada
Minimum Clearance to
Combustibles and Hearth
Requirements
E. (US)
E.(Can)
F. (US)
F. (Can)
DATE OF MANUFACTURE
Mar
Apr
May
Jun
Jul
Aug
100-01434
SERIAL NO:
Factory-Built
Masonry
(Z.C.) Fireplace
Fireplace
Installations
Installations
30.0 in. (762 mm)
A.
13.0 in. (331 mm)
12.0 in. (305 mm)
B.
9.5 in. (242 mm)
12.0 in. (305 mm)
C.
12.0 in. (305 mm)
24.0 in. (610 mm)
D.
15.5 in. (394 mm)
16.0 in. (407 mm)
16.0 in. (407 mm)
18.0 in. (458 mm)
18.0 in. (458 mm)
6.0 in. (153 mm)
6.0 in. (153 mm)
8.0 in. (204 mm)
8.0 in. (204 mm)
Manufactured by:
TRAVIS INDUSTRIES, INC.
12521 Harbour Reach Drive
Mukilteo, WA 98275
www.travisproducts.com
Sep
Oct
Nov
Dec
33
0936
4151218

Advertisement