Using The Wall-Mounted Door Control; To Open The Door Manually - Chamberlain LiftMaster Security+ 3265CM-267 Owner's Manual

Table of Contents

Advertisement

Available languages

Available languages

Using the Wall-Mounted Door Control

THE MULTI-FUNCTION DOOR CONTROL
Press the push button to open
or close the door. Press again to
reverse the door during the
closing cycle or to stop the door
while it's opening.
Light feature
Press the Light button to turn
the opener light on or off. It will not control the opener
lights when the door is in motion. If you turn it on and
then activate the opener, the light will remain on for 4-1/2
minutes. Press again to turn it off sooner. The 4-1/2
minute interval can be changed to 1-1/2, 2-1/2, or 3-1/2
minutes as follows: Press and hold the Lock button until
the light blinks (about 10 seconds). A single blink indicates
that the timer is reset to 1-1/2 minutes. Repeat the
procedure and the light will blink twice, resetting the timer
to 2-1/2 minutes. Repeat again for a 3-1/2 minute interval,
etc., up to a maximum of four blinks and 4-1/2 minutes.
Lock feature
Designed to prevent operation of the door from
hand-held remote controls. However, the door will open
and close from the Door Control, the Outside Keylock and
the Keyless Entry Accessories.
To activate, press and hold the Lock button for 2 seconds.
The push bar light will fl ash as long as the Lock feature is
on.
To turn off, press and hold the Lock button again for
2 seconds. The push bar light will stop fl ashing. The Lock
feature will also turn off whenever the "learn" button on
the motor unit panel is activated.
Additional features when used with the 3-Button
hand-held remote
A) To control the opener lights:
In addition to operating the door, you
may program the remote to operate
the lights.
1. With the door closed, press and hold a small remote
button that you want to control the light.
2. Press and hold the Light button on the
Multi-Function door control.
3. While holding the Light button, press and hold the Lock
button on the door control.
4. After the opener lights fl ash, release all buttons.
B) To operate one door using all three buttons on the
hand-held remote:
You may program the remote
to open the door with the large
Push
button, close it with the middle
Button
button, and stop the door's
Lock
movement with the third button.
Button
NOTE: If remote is already
Light
programmed, you must fi rst erase all codes. See
Button
Programming.
1. With the door closed, press and hold the large remote
push button.
2. Press and hold the Lock button on the door control.
3. Press and hold the door control push bar.
4. After the opener lights fl ash, release all buttons.

To Open the Door Manually

To prevent possible SERIOUS INJURY or DEATH from
a falling garage door:
• If possible, use emergency release handle to
disengage trolley ONLY when garage door is
CLOSED. Weak or broken springs or unbalanced
door could result in an open door falling rapidly
and/or unexpectedly.
• NEVER use emergency release handle unless garage
doorway is clear of persons and obstructions.
• NEVER use handle to pull door open or closed. If
rope knot becomes untied, you could fall.
The door should be fully
closed if possible. Pull
down on the emergency
release handle and lift
the door manually. To
reconnect the door to the
opener, press the door
control push bar.
The lockout feature
prevents the trolley from
reconnecting automatically.
Pull the emergency release
handle down and back
(toward the opener). The
door can then be raised and
lowered manually as often
as necessary. To disengage
the lockout feature, pull
the handle straight down.
The trolley will reconnect
on the next UP or DOWN
operation, either manually
or by using the door control
or remote.
27
Stop
Emergency
Release Handle
(Pull Down)
MANUAL DISCONNECT POSITION
Emergency
Release Handle
(Down and Back)
LOCKOUT POSITION
Open
Close
Trolley
Release
Arm
Trolley
Release
Arm

Advertisement