Troubleshooting - International comfort products 40MBFQ Installation Instructions Manual

Floor console ductless system
Table of Contents

Advertisement

TROUBLESHOOTING

For ease of service, the systems are equipped with a diagnostic
code display LEDs on both the indoor and outdoor units.
The indoor diagnostic display is a combination of flashing LEDs
on the display panel or the front of the unit. Some indoor units
display error codes specifying failure modes in outdoor units.
INDOOR UNIT DIAGNOSTIC GUIDES
OPERATION LAMP
TIMER LAMP
1 time
☆ 2 times
☆4 times
☆5 times
☆6 times
☆7 times
☆8 times
☆1 time
☆2 times
☆3 times
☆4 times
☆5 times
☆6 times
☆7 times
☆8 times
☆9 times
☆10 times
☆1 time
☆2 times
☆3 times
☆4 times
☆5 times
☆6 times
☆7 times
☆8 times
For additional diagnostic information, refer to the Service Manual.
Table 8—Indoor Unit Diagnostic Guides
DISPLAY
X
E0
X
E1
X
E3
X
E4
X
E5
X
EC
X
EE
O
F0
O
F1
O
F2
O
F3
O
F4
O
F5
O
F6
O
F7
O
F8
O
F9
P0
P1
P2
P3
P4
P5
P6
P7
O (light) X (off) ☆ (flash)
If possible, always check the diagnostic codes displayed on the
indoor unit first.
The diagnostic codes displayed in the indoor and outdoor units are
listed in Table 8.
LED STATUS
Indoor unit EEPROM error
Communication malfunction between indoor and outdoor units
Indoor fan speed has been out of control
Indoor room temperature sensor T1 open circuit or short circuit
Evaporator coil temperature sensor T2 open circuit or short circuit
Refrigerant leakage detection
Water-level alarm malfunction
Current overload protection
Open circuit or short circuit of outdoor ambient temperature sensor T4
Open circuit or short circuit of condenser coil temperature sensor T3
Open circuit or short circuit of Compressor discharge temperature sensor T5
Outdoor unit EEPROM error
Outdoor fan speed has been out of control
T2B sensor error
Lifting-panel communication error
Lifting-panel malfunction
Lifting-panel is not closed
IPM malfunction
Over voltage or over low voltage protection
High temperature protection of compressor top
Outdoor low temperature protection
Inverter compressor drive error
Mode conflict
Compressor low-pressure protection
Outdoor IGBT temperature sensor error
13

Advertisement

Table of Contents
loading