5. TROUBLESHOOTING

Problem
The lighting/ventilator does not
switch on.
The lighting/ventilator does not
switch off.
After setting the lux value, the
presence detector remains
permanently on, regardless of the
setting.

6. TECHNICAL DATA

Dimensions:
Power supply voltage:
Circuit breaker:
Power consumption:
Relay contact channel 1 and 2:
Maximum load:
Maximum switching capacity:
EN
Cause
Internal error.
Defective lamp/ventilator.
Incorrect wiring.
There is no power supply voltage on
the sensor.
Incorrectly set lux value.
Switch-off delay set too long.
The presence detector is still detecting
movement.
Power supply voltage fluctuations.
The presence detector is subject to
temperature fluctuations.
Internal error.
59 x 127 mm (HxW)
230 Vac ± 10%
maximum MCB rating 10 A*
< 1 W
NO (max. 10 A), light- and motion-sensitive
incandescent lamps (2300 W)
230 V halogen lamps (2300 W)
all low-voltage halogen lamps (1200 VA)
fluorescent lamps (non-compensated) (1200 VA)
economy lamps (CFLi) (350 W)
ventilation motor (690 VA)
led lamps 230 V (350 W)
140 uF
Solution
Switch the mains power off for at
least five seconds and then switch it
back on.
Test whether the lamp/ventilator itself
is still working.
Check the wiring against the wiring
diagram.
Check whether there is power supply
voltage on the sensor.
Ensure the lux value is set to the
desired light intensity.
Ensure the switch-off delay is not set
too long (using the TIME key).
Leave the detection zone to prevent to
presence detector from re-activating.
Ensure the power supply voltage is
constant.
Ensure the presence detector is not
pointed towards an object that may
cause temperature fluctuations,
such as air conditioning or a heating
installation.
Switch the mains power off for at
least five seconds and then switch it
back on.
20