PROBLEM
A. CONSTANT SPARKING AT
SURFACE BURNER(S)
B. INTERMITTENT SPARKING
AT SURFACE BURNER(S)
C. POOR IGNITION AT SUR-
FACE BURNER(S)
2 2
2 2
POSSIBLE CAUSE
Reverse Polarity at outlet or unit
Ground wire disconnected at outlet or
inside unit
Spark module(s) wired incorrectly or defec-
tive
Electrode not positioned properly
Burner head not properly positioned on
inner distribution ring
Defective micro switch at burner valve
Cut or splice in electrode wire
Dirty electrode
Cracked or damaged electrode
Cut or splice in electrode wire
Bad wire connection at spark module(s)
Defective spark module(s)
Burner head not properly seated on inner
distribution ring
Electrode not positioned properly
Partially plugged ports in burner head
O-rings not properly installed
Debris on inner distribution ring
Inner distribution ring has burr or crack
Improper Gas orifice
Gas pressure
Improper gas type
S S E E R R I I E E S S
S S E E R R I I E E S S
May have to call an electrician. Check internal
connections, may have to wire correctly
May have to call an electrician. Check internal
connections, may have to wire correctly
Rewire spark module(s) or replace
Reposition electrode. Electrode should be seat-
ed down to cooktop pan. (Refer to Tech Data)
Rotate to correct position and advise owner
Replace micro switch
Replace electrode wire
Clean with wire brush
Replace electrode
Replace electrode wire
Repair wire connection
Replace spark module(s)
Rotate to correct position and advise owner
Reposition electrode. Electrode should be seat-
ed down to cooktop pan. (Refer to Tech Data)
Clear/clean as necessary
Install properly or replace if defective
Clean/remove debris
Replace inner distribution ring
Check orifice stamp number
Check gas pressure with a manometer
Check for gas type and advise owner if improp-
er. May have to convert unit to LP/Natural gas