The display
shows CLOSE DOOR
The display
shows an
alarm/error
code
Drying takes a
long time.
The washing
does not become
dry.
The sealing strip
does not seal
tightly, the door
is ajar.
34
Action
1. Check that the door closes tightly so that the door switch is activated.
(Located at the bottom of the cabinet on the cover plate in front of the
heat pump unit).
2. If necessary, try to tape the switch in position and check whether the
warning on the display disappears.
3. If none of the above work contact Service.
This should normally not happen, but if an alarm or error code appears,
fi rst try to reset the alarm by holding the START/STOP button down for
5 sec.
If the problem persists, consult the error code list on page 33 to try to
locate the fault. Try to rectify the indicated fault, but if the fault persists
the unit (the heat pump box) must be replaced. Contact Service.
1. Clean the fi lter (this should preferably be done after each drying
operation).
2. Check that the water tank is empty.
3. Make sure that the correct programme has been selected for the
type of washing.
4. Make sure that the washing is not soaking wet (poorly spun).
5. Make sure that too much washing has not been hung up.
6. Adjust parameters P2072 and P2071 as described in the chapter on
SETTING DRYING PROGRAMME.
1. Make sure that the correct programme has been selected for the type
of washing.
2. Make sure that too much washing has not been hung up.
3. Adjust parameters 2072 and 2071 as described in the chapter
SETTING DRYING PROGRAMME.
1. Check that the cabinet is level. Check with a spirit level, adjust if
necessary with the adjusting feet.
2. Check that the cleaning fi lter and its holder are correctly fi tted. The
holder must be pressed down against the underlying heat pump unit
and locked with the revolving mounting brackets to seal properly.
3. Check that no litter, gravel or similar has ended up beneath the holder
of the cleaning fi lter, as the fi lter will not seal satisfactorily if this is the
case.