12-10. SMOOTH MAINTENANCE
1. Select ˝Service˝ from the Main menu, and press the [
Select ˝Check˝ with the F1 or F2 button, and press the [
Select ˝Smooth maintenance˝ with the F1 or F2 button, and
press the [
] button.
2. Set each item.
Select the item to be changed with the F1 or F2 button.
Select the required setting with the F3 or F4 button.
■ <Ref.address>setting [ 0 ] – [ 15 ]
■ <Stable mode>setting [ Cool ] / [ Heat ] / [ Normal ]
Press the [
] button, Fixed operation will start.
Note: Stable mode will take approx. 20 minutes.
3. The operation data will appear.
The Compressor-Accumulated operating (COMP. run) time is 10-hour unit, and
the Compressor-Number of operation times (COMP. ON/OFF) is a 100-time
unit (fractions discarded).
Navigating through the screens
• To go back to the Service menu .............. [
• To return to the previous screen ............... [
OCH753A
] button.
] button.
] button
] button
51
Check menu
Error history
Diagnosis
Smooth maintenance
Request code
Service menu:
Cursor
F1
F2
F3
F4
Smooth maintenance
Ref.address
Stable mode
Cool
/ Heat/ Normal
Begin:
-Address+
Cursor
Smooth maintenance
Ref.address
Stable mode
Cool
/ Heat/ Normal
Stabilization→Collecting
Exit:
Smooth maintenance
Cool
Ref. address
A
COMP. current
Hr
COMP. run time
times
COMP. On / Off
Hz
COMP. frequency
Return:
Page
Smooth maintenance
Ref.address
Cool
Sub cool
OU TH4 temp.
OU TH6 temp.
OU TH7 temp.
Return:
Page
Smooth maintenance
Cool
Ref.address
IU air temp.
IU HEX temp.
Hr
IU filter time
Return: