Download Print this page

Jenn-Air JBZFR18IGX Manual page 22

Hide thumbs Also See for JBZFR18IGX:

Advertisement

S I T E P R E P
3 . C H E C K T H E W A T E R S U P P LY
 W at er su p p ly m eet s local p lu m b in g cod es.
 W at er sh u t off in b ase cab in et , as sh ow n ,
or accessib le area.
 Access h ole t h rou g h t h e cab in et is w it h in 1/2"
(1.3 cm ) of t h e rear w all.
 In st all an y ad d it ion al t u b in g on ly w h ere
t em p erat u res rem ain ab ove f reezin g .
Ch eck for leaks.
 Not u sin g a p iercin g -t yp e or 3/16" (4 .8 m m )
sad d le valve. See ref rig erat or d ealer for
sad d le-t yp e valve kit t h at com p lies w it h
local p lu m b in g cod es.
 If w at er p ressu re t o reverse osm osis syst em
is less t h an 4 0 t o 60 p si (276 t o 414 k Pa):
• Ch eck sed im en t fi lt er t o see if it is b locked .
Rep lace fi lt er if n ecessary.
• Allow t h e st orag e t an k t o refi ll aft er
h eavy u sag e.
• Rem ove t h e w at er fi lt er cart rid g e.
No fi lt er b yp ass is n ecessary.
I F YO U HAVE Q UE S TI O N S A B O UT YO UR WAT E R S UPPLY ,
?
CALL A LI CE N S ED , Q UA L I FIE D P L UMB ER.
22 I N T R O D U C T I O N
W A T E R S U P P LY R E Q U I R E M E N T S
W ater Pressure
30 – 120 p si (207 – 827 k Pa)
W ater Pressure to
M in im u m 4 0 – 60 p si
Reverse Osm osis
(276 – 414 k Pa)
System
Excess W ater Line
30 " (76.2 cm )
for Connect ion
Supply
1/4" OD cop p er, b raid ed
st ain less st eel or PEX t u b in g
W ater shutoff
(w it hin 1/ 2" of rear w all)
Access hole

Advertisement