HeatWaVe Kit (not epa approVed)

listinGs and code
approVals
This Kit has been approved for use with
Models EX90 / R90. This kit has been tested in
accordance with National Safety Standards, and
has been certified by OMNI Test Laboratories
for installation and operation in Canada as
described in these Installation and Operating
Instructions.
Check with your local building code agency
before you begin your installation to ensure
compliance with local codes, including the
need for "permits" and follow-up inspections. If
any problems are encountered regarding code
approvals, or if you wish clarification on any of
the instructions contained here, contact your
local dealer.
included with Kit:
1
946-010 20 ft. (6.1 m) of 6" dia. flex pipe
1
946-517 Fan housing assembly
1
910-412 Variable wall rheostat
1
946-006 Air register
1
946-005 Register adaptor frame (thick)
1
946-000 Round Duct collar
1
946-001 Oval Duct collar
1
946-002 Duct adaptor (round to oval)
1
946-045 Insulation (60")
Hardware package
if any parts are missing or damaged, contact
your dealer before starting installation. do
not install a damaged kit.
32
General
inforMation
The Heat Wave Air Duct Kit increases the
effectiveness of your fireplace by dispersing
warm air from the fireplace to remote locations in
the same room or other rooms in your home.
Up to two kits may be installed on the fireplace.
please note: Only 1 HeatWave kit may be
operated at one time. This includes the internal
blower option as well.

important installation notes

1) The appliance installation must conform
with local codes or, in the absence of local
codes, with the current Canadian or National
Gas Codes, CAN1-B149 or ANSI Z223.1
Installation Codes.
2) The appliance when installed, must be
electrically grounded in accordance with
local codes, or in the absence of local codes
with the current National Electrical Code,
ANSI/NFPA 70 or CSA C22.1 Canadian
Electrical Code.

parts

Diagram 1: Guide for possible air duct runs and locations. Keep duct length and number of
bends to a miniumum. Maximum duct length is 20 ft. (6.1m) per kit.
3) This kit is tested and safe when installed in
accordance with this installation manual.
Please read all instructions before starting
installation and follow all instructions
carefully during installation.
4) Installation of this kit must be performed by
a qualified service technician.
5) The Heat Wave Kit must be installed only
as specified. Any modifications of the kit or
components will void the warranty and may
cause a fire hazard.
6) Plan the location of the fireplace and the
warm air duct runs, see diagram 1 as a
guide for possible duct runs and locations.
Maximum duct run: 20 ft. (6.1m) per
kit.
note: Airflow through the duct system is
affected by the duct length and number of
bends. Keep the length and bends to a
minimum to maximize performance.
FPI FP90 Wood Fireplace