General Safety Information; Installation Checklist; Heatwave Duct System Optional Kit - Regency City CV72E-NG11 Owners & Installation Manual

Zero clearance direct vent gas fireplace single sided
Table of Contents

Advertisement

installer's information

General Safety Information

1. The appliance installation must conform with
local codes or, in the absence of local codes,
with the current Canadian or National Gas
Codes, CAN1-B149 or ANSI Z223.1 Installation
Codes.
2. See general construction and assembly
instructions. The appliance and vent should be
enclosed.
3. This appliance must be connected to the
specified vent and termination cap to the outside
of the building envelope. Never vent to another
room or inside a building. Make sure that the
vent is fitted as per Venting instructions.
4. Inspect the venting system annually for blockage
and any signs of deterioration.
5. Venting terminals shall not be recessed into a
wall or siding.
6. Any safety glass removed for servicing must
be replaced prior to operating the appliance.
7. To prevent injury, do not allow anyone who is
unfamiliar with the operation to use the fireplace.
8. Wear gloves and safety glasses for protection
while doing required maintenance.
9. Be aware of electrical wiring locations in walls
and ceilings when cutting holes for termination.
10. Under no circumstances should this appliance
be modified. Parts that have to be removed for
servicing should be replaced prior to operating
this appliance.
11. Installation and any repairs to this appliance
should be done by a qualified service person.
A professional service person should be called
to inspect this appliance annually. Make it a
practice to have all of your gas appliances
checked annually.
12. Do not slam shut or strike the glass door.
13. Under no circumstances should any solid fuels
(wood, paper, cardboard, coal, etc.) be used in
this appliance.
14. The appliance area must be kept clear and
free of combustible materials, (gases and other
flammable vapours and liquids).
| City Series CV72E
26

Installation Checklist

1. Locate appliance. Refer to the following sections:
a) Locating Your Fireplace
b) Clearances
c) Combustible Mantel Clearances
d) Framing & Finishing
e) Venting. See the "Venting Introduction" to
"Venting Arrangements" sections.
2. A ssemble Standoffs. Refer to the "Unit Assem-
bly Prior to Installation" section. (NOTE: must
be done before installing unit into fireplace.)
3. I nstall vent. See the "Horizontal Installations"
to "Installation Procedures" sections.
4. Wire 120 volt AC power to the supplied
receptacle box located on the lower left side
of the appliance. The Duplex receptacle and
cover are included in the manual package.
Note : This heater does not require a 120 volt
AC supply for burner operation, but it
is recommended as a primary power
source. Batteries should be used as a
secondary power source. 120 Volt AC
power is also required for the lights.
5. Install the remote battery box inside the junction
box. Hook the battery box to the wire marked
"receiver" - this will enable burner operation. If
120 Volt AC power was brought to appliance,
batteries are not required.
6. Make gas connections. T est the pilot. Must be as
per diagram. Refer to the "Gas Line Installation"
& "Pilot Adjustment" sections.
7. Install standard and optional features. Refer
to the following sections where applicable:
a. Barrier Safety Glass
b. Firebox (inner) glass
c. Log Set
d. Fireglass
e. Ceramic stones or other approved media
f. P ainted, enamel, or glass panels (panels
required)
g. Heatwave Kit
8. Plug 3 prong plug for the lights into the
receptacle. The 3 prong plug will be located
near the gas valve on the appliance.
9. Final check.
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly and operation fully explained to customer.
This includes:
1. Clocking the appliance to ensure the correct
firing rate (rate noted on label 46,500 Btu/h
NG/ 45,500 Btu/h LP) after burning appliance
for 15 minutes.
2. If required, adjusting the primary air to ensure
that the flame does not carbon. First allow the
unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.
Heatwave Duct System Optional
Kit
The HeatWave Air Duct Kit increases the
effectiveness of your fireplace by dispersing warm
air from the fireplace to remote locations in the same
room or other rooms in your home.
Up to two kits may be installed on the fireplace.
The HeatWave Duct Kit has different clearance
and framing requirements, check the HeatWave
manual for details.
Note: Using the optional heat wave kit does
not reduce the size of the ventilation opening,
which must be a minimum of 288 square inches
regardless.