Troubleshooting - Toro 323000001 Operator's Manual

60v max axial blower
Hide thumbs Also See for 323000001:
Table of Contents

Advertisement

Troubleshooting

Perform only the steps described in these instructions. All further inspection, maintenance, and repair work
must be performed by an authorized service center or a similarly qualified specialist if you cannot solve the
problem yourself.
Always remove the battery from the tool when troubleshooting, inspecting, maintaining, or cleaning the tool.
Problem
The tool does not start.
The tool does not reach full power.
The tool does not run or does not run
continuously.
The speed lock does not hold when
engaged.
The battery pack loses charge quickly.
The battery charger is not working.
The LED indicator light on the battery
charger is red.
Possible Cause
1. The battery is not fully installed in the
tool.
2. The battery pack is not charged.
3. The battery pack is damaged.
4. There is another electrical problem
with the tool.
1. The battery pack charge capacity is
too low.
2. The air vents are blocked.
1. There is moisture on the leads of the
battery pack.
2. The battery is not fully installed in the
tool.
3. The battery pack is low on charge.
1. The speed lock screw is loose.
1. The battery pack is over or under the
appropriate temperature range.
1. The battery charger is over or under
the appropriate temperature range.
2. The outlet that the battery charger is
plugged into does not have power.
1. The battery charger and/or battery
pack is over or under the appropriate
temperature range.
14
Corrective Action
1. Remove and then replace the battery
into the tool, making sure that it is fully
installed and latched.
2. Remove the battery pack from the tool
and charge it.
3. Replace the battery pack.
4. Contact an Authorized Service Dealer.
1. Remove the battery pack from the tool
and fully charge the battery pack.
2. Clean the air vents.
1. Allow the battery pack to dry or wipe it
dry.
2. Remove and then replace the battery
in the tool, ensuring that it is fully
installed and latched.
3. Charge the battery pack.
1. Tighten the speed lock screw by
turning the speed lock screw ¼ turn. If
the speed lock still does not hold when
engaged, turn the speed lock screw an
additional ¼ turn.
1. Move the battery pack to a place
where it is dry and the temperature is
between 5°C (41°F) and 40°C (104°F).
1. Unplug the battery charger and move
it to a place where it is dry and the
temperature is between 5°C (41°F)
and 40°C (104°F).
2. Contact your licensed electrician to
repair the outlet.
1. Unplug the battery charger and move
the battery charger and battery pack
to a place where it is dry and the
temperature is between 5°C (41°F)
and 40°C (104°F).

Advertisement

Table of Contents
loading

Table of Contents