Technical Specifications - Hach BioTector B3500s User Manual

Table of Contents

Advertisement

Section 3
TYPICAL TECHNICAL DATA
Enclosure:
Dimensions (HxWxD):
Weight:
Power Consumption:
Mains Connection:
Mains Wire Specification:
Signal Wire Specification:
FEATURES IN DETAIL
Display:
Data Storage:
SD/MMC Card:
Operation:
Language Options:
INPUT & OUTPUT SIGNALS
Standard Output:
Digital Output:
Data Transfer Port:
OPTIONAL FEATURES
Result Output:
Remote Control:
Industrial Interface:
Calibration:
Multi-stream:
Manual stream:
4-20mA Outputs:
Hazardous Area:

Technical Specifications

Fiberglass Reinforced Polyester
750mm x 500mm x 320mm
Enclosure height may increase to 1000mm, depending on system optional
features.
Typically 46 kg
100 W (VA)
115V AC, 60Hz or 230V AC, 50Hz (10%)
Other power options are available on request.
Number of Cores = 3, Current Rating minimum = 10 Amps, CSA (Cross
Sectional Area minimum) = 1.50mm
Number of Cores = 6 (+2 cores per additional signal), Current Rating
minimum = 1 Amp, CSA (Cross Sectional Area minimum) = 0.22mm
High Contrast 40 Character x 16 Line Backlit LCD with LED Backlight
Previous 9999 analysis data on screen in the microcontroller memory and
storage of data archive for the lifetime of the analyzer in the SD/MMC card
Previous 99 fault data on screen in the microcontroller memory and storage
of fault data archive for the lifetime of the analyzer in the SD/MMC card
Flash memory card for data transfer and for software & configuration updates
Microcontroller with BioTector OS3 Software and Membrane Keyboard
English, French, German
Other language options are available on request.
4 programmable 4-20mA analog output signal channel fitted as standard
Maximum impedance: 500 ohms
6 freely programmable system relays (volt free changeover contact with a
current rating of 1Amp at 30V DC)
One of the relays is preprogrammed as system fault relay as standard.
SD/MMC Card
TIC, TC, VOC, after correlation COD, BOD
Input for remote start / standby
Input for remote stream and range selection (up to 2 online streams)
Input for remote manual grab sample analysis
Network Control Unit for remote access over Internet or Intranet connection
using HTTP over TCP/IP protocol
Modbus, Profibus, Ethernet
(when any of the Modbus, Profibus or Ethernet option is selected, the digital
output signals are sent through the relevant device with its specific
communication protocol)
Automatic Calibration is available.
Calibration is not necessary between every 6 month service intervals.
Up to 2 sample input channels, which can be used for online streams
Manual grab sample channel, which can be used for automatic calibration.
Sample input channels may be configured as manual grab sample channels.
As individual signal up to maximum of 4 or as multiplex signal up to maximum
of 35. Maximum impedance: 500 ohms.
Certification options are available to European Standards (ATEX for Zone 2)
and to North American Standards (Class I Division 1 and Class I Division 2).
Other options are available on request.