Technical Data; Fault Repair; Vibration Noises From The Base Plate; Figure 050-1: Sealing Strip Installation - Miele T 982Series Technical Information

Table of Contents

Advertisement

T 9800/T 982x
1

Technical Data

Filter
Drying air temperature sensor

Table 050-1: Air Shield Data

3

Fault Repair

3.1

Vibration Noises from the Base Plate

Cause:
The exhaust module vibrates during appliance operation, which causes
vibrations in the base plate of the appliance. A buzzing or humming noise is
generated.
Remedy:
Insert a sealing strip (mat. no. 06808080) between the exhaust module
and the base plate:
1. Disconnect the machine from the power supply.
2. Remove the front panel; see Section 010-4.2
3. Place a thin flathead screwdriver between the exhaust module and the
base plate.
4. Use a thicker screwdriver to widen the gap between the exhaust module
and the base plate.
5. Remove the protective film from the sealing strip.
6. Insert the sealing strip into the gap and adhere it under the groove under
the exhaust module, making sure that the strip is centered.
7. Remove the thin screwdriver.
8. Replace the front panel.

Figure 050-1: Sealing Strip Installation

Flat filter
NTC (1R30)