Technical Information
1
Technical Data
Electronic (1N1)
Drying technology
Table 090-1: Technical Data
2
Function
2.1
Reversing (Electric) (T 9800)
Reversing rhythm: 5 minutes clockwise (default direction), 1.5-second
pause, 30 seconds running counterclockwise, 1.5-second pause.
During the clockwise run, shortly before the pause, heating is reduced to a
basic output of 1.9kW.
2.2
Reversing (Gas) (T 982x)
During the drying cycle, the gas dryer will not reverse for residual laundry
moisture levels below 20%.
For residual moisture levels greater than 20%, a maximum of 7 reversing
cycles will take place.
Reversing rhythm: 10 minutes running clockwise (default direction), 1.5-
second pause and 30 seconds running counterclockwise.
The burner is switched on at the start of the clockwise run, and it is switched
off 4 seconds before the start of the counterclockwise run. During the
counterclockwise run, the burner is always off.
2.3
Dryer Function after a Power Interruption
The dryer continues automatically at the point the program was interrupted.
2.4
Programming Functions
2.4.1
Resetting to Factory Settings
Resets all programming options to their factory settings.
Note:
The reset takes effect immediately; it's not possible to restore the previous settings!
Operating hours are not reset.
Not possible with service-department electronics.
Electric Heating
USA: EPWL 341
(single-board electronic)
Can be updated via optical PC interface installed
standard
Residual moisture sensing: conductivity test,
residual moisture sensor (B3/1), 1-rib sampling
Insufficient air detection via heater bank NTC 2R30
and drying air NTC 1R30
50
T 9800/T 982x
Gas Heating
USA: EPWL 345
(single-board electronic)