Cleanup - Graco 3A4133 Operation - Repair - Parts

Electric airless sprayers
Table of Contents

Advertisement

Cleanup

1.
Perform Pressure Relief Procedure,
page 12.
2.
Remove tip guard and Spray Tip. For
additional information, see separate gun
manual.
3.
Remove fluid intake and drain tube from
paint, wipe excess paint off outside.
3A4187C
4.
Place fluid intake in flushing fluid. Use
water for water base paint and mineral
spirits for oil-based paint. Place drain
tube in waste pail.
5.
Turn prime valve horizontal.
6.
Increase pressure 1/2 turn to start motor.
Hold gun against paint pail. Disengage
trigger lock. Trigger gun and increase
ti29459a
pressure until the pump runs steady and
flushing fluid appears.
ti29642a
ti24709a
Operation
ti24710a
23