Section 6: Integral Proximity Switch Mounting

May 2020
Section 6: Integral Proximity
(Only with Prox Prep Factory Ordered Option)
A.
B.
C.
D.
14
Switch Mounting
Remove plastic plugs from proximity ports located on the back of the
actuator housing.
Insert switch and turn clockwise until switch touches ferrous activator on yoke,
then back off approximately 1/16 in. (1.6 mm).
Test switch by stroking actuator and verifying make and break of switch.
Repeat procedure for second switch if required.