WALL SWITCH INSTALLATION
The installation of a wall switch allows you to activate the gas control
valve without normal household electricity since valve operates on
millivolt current supplied by heat generated by the thermopile. To
install wall switch:
1. Remove front refractory access panel by lifting up and angling
out of firebox opening (see Figure 13).
2. Use wire and connectors provided. Attach red wire to terminal
marked TH/TP on control valve. Attach white wire to blade con-
nector on open end of safety circuit wiring (see Wiring Diagram,
Page 20).
NOTE: If any of the original wire from unit control must be replaced,
use the same type or a higher rated wire (25 ft. maximum length).
WARNING: Do not wire remote wall switch to main
power supply (Standard 120v household current).
3. Locate wall switch in a convenient location.
4. After wire connections are complete, replace refractory access
panel.
NOTE: If using optional wireless hand-held remote control, the wall switch is no longer operational.
Installing Receiver
1. Remove front refractory access panel by lifting up and angling out of firebox opening (see Figure 13) to expose controls.
2. Disconnect wall switch wires from TH and TH/TP terminals on control valve (see Figure 14).
3. See remote instructions for further information.
NOTE: If any of the original wire as
supplied must be replaced, use 18 AWG
TYPE CL2 (UL) 105 C (25 ft. length
MAXIMUM) or equivalent.
900806-00F

INSTALLATION

INSTALLING WIRELESS HAND-HELD REMOTE CONTROL MRC SERIES
Figure 14 - Wall Switch Wiring Diagram
SuperiorFireplaces.us.com
Figure 13 - Removing Front Refractory Access Panel
Route Millivolt
Wires (Supplied)
Through Gas Line
Conduit Sleeve
To Thermopile
and Switches
Wall Switch
(Not Supplied)
(Back View)
11