Advertisement

®
INSTRUCTION MANUAL
Gold Wrist Blood Pressure Monitor
Model BP4350
2829250-8D

Advertisement

Table of Contents
loading

Summary of Contents for Omron BP4350

  • Page 1 ® INSTRUCTION MANUAL Gold Wrist Blood Pressure Monitor Model BP4350 2829250-8D...
  • Page 2: Table Of Contents

    Table of Contents Introduction ....................3 Important Safety Information ................4 1. Know Your Monitor ................8 2. Preparation ..................14 3. Using Your Monitor without a Smart Device ........21 4. Using Your Monitor with a Smart Device ..........24 5. Using Memory Function ...............27 6.
  • Page 3: Introduction

    Safety Instructions This instruction manual provides you with important information about the OMRON BP4350 Wrist Blood Pressure Monitor. To ensure the safe and proper use of this monitor, READ and UNDERSTAND all of these instructions. If you do not understand these instructions or have any questions, contact 1-800-634-4350 before attempting to use this monitor.
  • Page 4: Important Safety Information

    Important Safety Information Read the Important Safety Information in this instruction manual before using this monitor. Follow this instruction manual thoroughly for your safety. Keep for future reference. For specific information about your own blood pressure, CONSULT WITH YOUR PHYSICIAN. Indicates a potentially hazardous situation which, if not Warning avoided, could result in death or serious injury.
  • Page 5 Data Transmission • This product emits radio frequencies (RF) in the 2.4 GHz band. DO NOT use this product in locations where RF is restricted, such as on an aircraft or in ® hospitals. Turn off the Bluetooth feature in this monitor and remove batteries when in RF restricted areas.
  • Page 6 • Ensure that this monitor has acclimated to room temperature before taking a measurement. Taking a measurement after an extreme temperature change could lead to an inaccurate reading. OMRON recommends waiting for approximately 2 hours for the monitor to warm up or cool down when...
  • Page 7 Battery Handling and Usage • DO NOT insert batteries with their polarities incorrectly aligned. • ONLY use 2 “AAA” alkaline batteries with this monitor. DO NOT use other types of batteries. DO NOT use new and used batteries together. DO NOT use different brands of batteries together.
  • Page 8: Know Your Monitor

    1. Know Your Monitor Contents Monitor, 2 “AAA” alkaline batteries, storage case, instruction manual, quick start guide Monitor a. Wrist cuff (Wrist circumference 5.3" to 8.5" (13.5 cm to 21.5 cm)) b. Display c. [User ID selection] switch d. [Memory] button e.
  • Page 9 Display and Symbols...
  • Page 10 Date and time display Average value symbol Appears when viewing the average of the latest 2 or 3 readings taken within the most recent 10 minute timeframe. Memory symbol Appears when viewing readings stored in the memory. Systolic blood pressure reading Diastolic blood pressure reading Pulse display / Memory number Pulse rate appears after the measurement.
  • Page 11 Morning average symbol Appears when viewing the weekly average readings taken in the morning over the past 4 weeks. User ID symbol The user ID number appears when selecting the user with [user ID selection] switch. High symbol Appears if your systolic blood pressure is 130 mmHg or above and/or the diastolic blood pressure is 80 mmHg or above.
  • Page 12 Irregular heartbeat symbol Appears along with readings when Normal Heartbeat an irregular rhythm is detected 2 or Pulse more times during a measurement. Blood pressure An irregular heartbeat rhythm is defined as a rhythm that is 25% less or 25% more than the average Irregular Heartbeat Short Long rhythm detected while your monitor...
  • Page 13 Classification of BP (Blood Pressure) ACC/AHA 2017 Hypertension guidelines define categories of BP in adults as below. Categories of BP in Adults* BP Category Systolic BP Diastolic BP Normal < 120 mmHg < 80 mmHg Elevated 120 - 129 mmHg and <...
  • Page 14: Preparation

    2. Preparation Installing Batteries Push down on the hook of the battery cover and pull downward. Insert 2 “AAA” alkaline batteries as indicated in the battery compartment. Close the battery cover. Note • When the “ ” symbol flashes on the display, it is recommended you replace batteries.
  • Page 15 • As soon as batteries are correctly installed, the year flashes on the display of your monitor. • The date and time will automatically be set when the monitor is paired with the compatible OMRON app. Refer to section 4.1. Press the button once to adjust the year.
  • Page 16 Note • If you need to reset the date and time, replace batteries or press and hold the button until the year flashes, and set the date and time as above steps. Blood Pressure Measurement Tips To help ensure an accurate reading, follow these directions: •...
  • Page 17 • The blood pressure can differ between the right wrist and the left wrist, and the measured blood pressure values can be different. OMRON recommends to always use the same wrist for measurement. If the values between both wrists differ substantially, please check with your physician as to which wrist to use for your measurements.
  • Page 18 Position the wrist cuff leaving a clearance of 0.5 inch (1 to 2 cm) between the cuff and the bottom of your palm. 0.5 inch (1 to 2cm) Wrap the wrist cuff firmly around your wrist. Do not apply over clothing.
  • Page 19 Sitting Correctly To take a measurement, you need to be relaxed and comfortably seated in a room with a comfortable temperature. Place your elbow on the table to support your arm. • Sit in a chair with your legs uncrossed and your feet flat on the floor.
  • Page 20 Selecting a User ID Your monitor is designed to take measurements and store the readings in the memory for 2 people using the [user ID selection] switch. Select your user ID (1 or 2).
  • Page 21: Using Your Monitor Without A Smart Device

    3. Using Your Monitor without a Smart Device Taking a Measurement You can use your monitor without pairing to a smart device. To pair your monitor with a smart device, refer to section 4.1. Note • To stop the measurement, press the [START/STOP] button once to deflate the wrist cuff.
  • Page 22 Monitor height Heart Zone Indicator Any locator bar (-) above the “ ” symbol Wrist is too high appears. Proper position The “ ” symbol lights in blue. Any locator bar (-) below the “ ” symbol Wrist is too low appears.
  • Page 23 Remain still and do not move or talk until the entire measurement process is completed. As the cuff inflates, your monitor automatically determines your ideal inflation level. This monitor detects your blood pressure and pulse rate during inflation. The “ ”...
  • Page 24: Using Your Monitor With A Smart Device

    Download and install the compatible OMRON app onto your smart device. If you already have the compatible OMRON app and have created your account, open the app and add your new monitor. Open the app on your smart device and follow the instructions.
  • Page 25 • Please be aware that OMRON will not be responsible for the loss of data and/or information in the app. • Only compatible OMRON apps should be used with this monitor to help ensure correct data transfer.
  • Page 26 Disabling/Enabling Bluetooth Warning • This product emits radio frequencies (RF) in the 2.4 GHz band. DO NOT use this product in locations where RF is restricted, such as on an aircraft or in hospitals. Turn off the Bluetooth feature in this monitor and remove batteries when in RF restricted areas.
  • Page 27: Using Memory Function

    5. Using Memory Function Your monitor automatically stores up to 100 readings per user. Note • This monitor can be used by multiple users. Refer to section 2.6 to switch user. Make sure which user ID stores your own readings. Viewing the Readings Stored in Memory Select your user ID.
  • Page 28 Press the button repeatedly to scroll through the previous readings stored in the memory. Viewing the Average Reading Your monitor can calculate an average reading based on the latest 2 or 3 readings taken within 10 minutes span. Select your user ID. When your monitor is off, press and hold the button for more than 2 seconds.
  • Page 29 Press the button repeatedly to display the average for the previous weeks. Your monitor displays “-1 WEEK” for the previous week's average, to “-3 WEEK” for the oldest set of averages. Press the [START/STOP] button to turn off your monitor. Morning Weekly Average Calculation This is the average for the measurements taken during the morning (4:00am - 9:59am) between Sunday and Saturday.
  • Page 30: Other Settings

    6. Other Settings Disabling/Enabling Heart Zone Indicator The heart zone indicator is enabled as default. Select your user ID. When your monitor is off, press and hold the button for more than 10 seconds. Note • Your monitor will automatically turn off after 3 seconds from the completion. •...
  • Page 31 While holding the button down, press and hold the [START/STOP] button for more than 2 seconds. Note • All readings will be deleted. You cannot partially delete the readings stored in the memory. Restoring Your Monitor to the Default Settings To delete all the information stored in your monitor, follow the instructions below.
  • Page 32: Error Messages And Troubleshooting

    7. Error Messages and Troubleshooting In case of any of the below problems occur during measurement, first check that no other electrical device is within 12 inches (30 cm). If the problem persists, please refer to the table below. Display/ Possible Cause Solution Problem...
  • Page 33 Display/ Possible Cause Solution Problem Apply the wrist cuff correctly, then take appears another measurement. Refer to section 2.4. The pulse rate is not Remain still and sit correctly during a detected correctly. measurement. appears If the “ ” symbol continues to appear, we recommend you to consult with your physician.
  • Page 34 Display/ Possible Cause Solution Problem More than 80 readings are not transferred. This monitor is ready for Pair or transfer your readings to the flashes pairing or transferring app so you can keep them in memory your readings. in the app, and this error symbol disappears.
  • Page 35 Display/ Possible Cause Solution Problem appears or the monitor is Batteries are depleted. Immediately replace all batteries with turned off 2 new alkaline batteries. Refer to unexpectedly section 2.1. during a measurement Batteries are completely No power. depleted. Nothing appears on the Check the battery installation for Battery polarities are not display of the...
  • Page 36: Maintenance

    8. Maintenance Maintenance To protect your monitor from damage, please follow the directions below: • Changes or modifications not approved by the manufacturer will void the user warranty. Caution • DO NOT disassemble or attempt to repair this monitor or other components. This may cause an inaccurate reading.
  • Page 37: Specifications

    9. Specifications Model BP4350 HEM-6232T-Z Display LCD digital display Cuff pressure range 0 to 299 mmHg Blood pressure SYS: 60 to 260 mmHg measurement range DIA: 40 to 215 mmHg Pulse measurement 40 to 180 beats / min. range Pressure: ±3 mmHg Accuracy Pulse: ±5% of display reading...
  • Page 38 Weight Approximately 3.2 oz. (91 g) not including batteries Approximately 3.6" (w) × 2.5" (h) × 0.5" (l)* Dimensions (91 mm × 63 mm × 13 mm) (not including the wrist cuff) Measurable wrist 5.3" to 8.5" (13.5 to 21.5 cm) circumference Memory Stores up to 100 readings per user...
  • Page 39 Pictogram on the Product Indicates the correct positioning for the monitor on the wrist. About a wireless communication interference This product operates in an unlicensed ISM band at 2.4 GHz. In the event this Product is used near other wireless devices such as microwave and wireless LAN, which operate on the same frequency band as this Product, there is a possibility that interference may occur.
  • Page 40: Fcc/Ic Statement

    10. FCC/IC Statement FCC CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of FCC Rules and Industry Canada license- exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 41 This equipment complies with FCC/IC radiation exposure limits set forth for an uncontrolled environment and meets the FCC radio frequency (RF) Exposure Guidelines and RSS-102 of the IC radio frequency (RF) Exposure rules. This equipment has very low levels of RF energy that are deemed to comply without testing of specific absorption ratio (SAR).
  • Page 42: Limited Warranty

    11. Limited Warranty Your BP4350 Wrist Blood Pressure Monitor, excluding batteries, is warranted to be free from defects in materials and workmanship appearing within 5 years from the date of purchase, when used in accordance with the instructions provided with the monitor.
  • Page 43 This warranty provides you with specific legal rights, and you may have other rights that vary by jurisdiction. Because of special local requirements, some of the above limitations and exclusions may not apply to you. FOR CUSTOMER SERVICE For USA - OmronHealthcare.com Visit our web site at: For Canada - OmronHealthcare.ca Call toll free:...
  • Page 44: Guidance And Manufacturer's Declaration

    Documents in the Scope of IEC60601-1-2:2014 Important information regarding Electro Magnetic Compatibility (EMC) BP4350 manufactured by OMRON HEALTHCARE Co., Ltd. conforms to IEC60601-1-2:2014 Electro Magnetic Compatibility (EMC) standard. Further documentation in accordance with this EMC standard is available at OmronHealthcare.com/...
  • Page 45 ® The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by OMRON HEALTHCARE Co., Ltd. is under license. Other trademarks and trade names are those of their respective owners.

Table of Contents