Meter Functions; Mode Switch Settings - Miller XMT 350 VS Auto-Line w/WCC Owner's Manual

Hide thumbs Also See for XMT 350 VS Auto-Line w/WCC:
Table of Contents

Advertisement

6-2. Meter Functions

.
The meters display the actual weld output values for approximately three seconds after the arc is broken.
Mode
Scratch
Start TIG
Lift-Arc TIG
Stick
MIG

6-3. Mode Switch Settings

.
Stick mode provides the Adaptive Hot Start™ feature, which automatically increases the output amperage at the start of a weld should the start
require it. This eliminates electrode sticking at arc start.
Mode Switch Setting
Scratch Start TIG
Lift-Arc TIG
Stick
FCAW (no gas)
MIG/FCAW (with gas)
.
On non-WCC power source output (V) is controlled at the power source.
OM-252 340 Page 26
Meter Reading At Idle
V
71.7
Actual Volts (OCV)
Preset Amps
V
13.6
Preset Volts
Preset Amps
V
71.7
Actual Volts (OCV)
Preset Amps
V
24.5
Preset Volts
Blank
Process
GTAW
GTAW − See Section 6-4
SMAW
FCAW (no gas)
FCAW/GMAW
Meter Reading While Welding
A
85
10.3
Actual Volts
A
85
10.3
Actual Volts
A
85
24.5
Actual Volts
A
24.5
Actual Volts
V
A
85
Actual Amps
V
A
85
Actual Amps
V
A
85
Actual Amps
V
A
250
Actual Amps
Output Control
Electrode Hot
Electrode Hot
Electrode Hot
At Wire Feeder
At Wire Feeder

Advertisement

Table of Contents
loading