Mitsubishi Electric FR-E720-0.4K Instruction Manual page 40

Hide thumbs Also See for FR-E720-0.4K:
Table of Contents

Advertisement

Parameter list
Parameter
Name
NET mode operation
550
command source selection
PU mode operation command
551
source selection
555
Current average time
556
Data output mask time
Current average value monitor
557
signal output reference current
Energization time carrying-
563
over times
Operating time carrying-over
564
times
571
Holding time at a start
611
Acceleration time at a restart
653
Speed smoothing control
Regeneration avoidance
665
frequency gain
800
Control method selection
859
Torque current
Input phase loss protection
872

selection
Regeneration avoidance
882
operation selection
Regeneration avoidance
883
operation level
Regeneration avoidance
885
compensation frequency limit
value
Regeneration avoidance
886
voltage gain
888
Free parameter 1
889
Free parameter 2
C0
FM terminal calibration
(900)

C2
Terminal 2 frequency setting
(902)

bias frequency
C3
Terminal 2 frequency setting
(902)
bias

125
Terminal 2 frequency setting
(903)

gain frequency
C4
Terminal 2 frequency setting
(903)
gain

C5
Terminal 4 frequency setting
(904)

bias frequency
C6
Terminal 4 frequency setting
(904)

bias
126
Terminal 4 frequency setting
(905)
gain frequency

C7
Terminal 4 frequency setting
(905)

gain
Frequency setting voltage bias
C22
frequency (built-in
(922)

potentiometer)
C23
Frequency setting voltage bias
(922)
(built-in potentiometer)

Frequency setting voltage gain
C24
frequency (built-in
(923)

potentiometer)
C25
Frequency setting voltage gain
(923)

(built-in potentiometer)
990
PU buzzer control
36
Setting
Initial
Parameter
Range
Value
0, 2, 9999
9999
2 to 4, 9999
9999
0.1 to 1.0s
1s
0 to 20s
0s

Inverter
0 to 500A
Rated
current
(0 to 65535)
0

(0 to 65535)
0
0 to 10s,
9999

9999
0 to 3600s,
9999
9999
0 to 200%
0%

0 to 200%
100%


20, 30
20
0 to 500A
(0 to ****),
9999

9999

0, 1
1

0, 1, 2
0
400VDC/
300 to 800V
780VDC

0 to 10Hz,
6Hz
9999
0 to 200%
100%
0 to 9999
9999
0 to 9999
9999
0 to 400Hz
0Hz
0 to 300%
0%
0 to 400Hz
60Hz
0 to 300%
100%
0 to 400Hz
0Hz
0 to 300%
20%
0 to 400Hz
60Hz
0 to 300%
100%
0 to 400Hz
0
0 to 300%
0
0 to 400Hz
60Hz
0 to 300%
100%
0, 1
1
Name
991
PU contrast adjustment
Pr.CL
Parameter clear
ALLC
All parameter clear
Er.CL
Fault history clear
Pr.CH
Initial value change list
Differ according to capacities.
6%: 0.75K or lower
4%: 1.5K to 3.7K
3%: 5.5K, 7.5K
2%: 11K, 15K
Differ according to capacities.
5s: 3.7K or lower
10s: 5.5K, 7.5K
15s: 11K, 15K
Differ according to capacities.
6%: 0.1K, 0.2K
4%: 0.4K to 7.5K
2%: 11K, 15K
The initial value differs according to the voltage class. (100V, 200V class/
400V class)
The range differs according to the Pr. 71 setting.
Set this parameter when calibrating the operation panel built-in
potentiometer for the FR-E500 series operation panel (PA02) connected
with cable.
The parameter number in parentheses is the one for use with the
operation panel (PA02) for the FR-E500 series or parameter unit (FR-
PU04/FR-PU07).
Available only for the three-phase power input model.
Setting
Initial
Range
Value
0 to 63
58
0, 1
0
0, 1
0
0, 1
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents