Mitsubishi Electric FR-E720-0.4K Instruction Manual page 37

Hide thumbs Also See for FR-E720-0.4K:
Table of Contents

Advertisement

7.2
Parameter list
REMARKS
  indicates simple mode parameters. (initially set to extended mode)
 The parameters surrounded by a black border in the table allow its setting to be changed during operation even if "0" (initial
value) is set in Pr. 77 Parameter write selection.
• Refer to
Chapter 4 of the Instruction Manual (Applied) for the detailed description of parameters.
Parameter
Name
 0
Torque boost
 1
Maximum frequency
 2
Minimum frequency
 3
Base frequency
Multi-speed setting (high
 4
speed)
Multi-speed setting (middle
 5
speed)
Multi-speed setting (low
 6
speed)
 7
Acceleration time
 8
Deceleration time
 9
Electronic thermal O/L relay
DC injection brake operation
10
frequency
DC injection brake operation
11
time
DC injection brake operation
12
voltage
13
Starting frequency
14
Load pattern selection
15
Jog frequency
Jog acceleration/deceleration
16
time
17
MRS input selection
High speed maximum
18
frequency
19
Base frequency voltage
Acceleration/deceleration
20
reference frequency
Acceleration/deceleration time
21
increments
22
Stall prevention operation level 0 to 200%
Stall prevention operation level
23
compensation factor at double
speed
24
Multi-speed setting (speed 4)
25
Multi-speed setting (speed 5)
26
Multi-speed setting (speed 6)
27
Multi-speed setting (speed 7)
Acceleration/deceleration
29
pattern selection
Regenerative function
30
selection
31
Frequency jump 1A
Setting
Initial
Parameter
Range
Value
6/4/3/2%
0 to 30%

0 to 120Hz
120Hz
0 to 120Hz
0Hz
0 to 400Hz
60Hz
0 to 400Hz
60Hz
0 to 400Hz
30Hz
0 to 400Hz
10Hz
0 to 3600/
5/10/15s
360s

0 to 3600/
5/10/15s
360s

Inverter
0 to 500A
rated
current
0 to 120Hz
3Hz
0 to 10s
0.5s
0 to 30%
6/4/2%

0 to 60Hz
0.5Hz
0 to 3
0
0 to 400Hz
5Hz
0 to 3600/
0.5s
360s
0, 2, 4
0
120 to 400Hz
120Hz
0 to 1000V,
9999
8888, 9999
1 to 400Hz
60Hz
0, 1
0
150%
0 to 200%,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0, 1, 2
0
0, 1, 2
0
0 to 400Hz,
9999
9999
Name
32
Frequency jump 1B
33
Frequency jump 2A
34
Frequency jump 2B
35
Frequency jump 3A
36
Frequency jump 3B
37
Speed display
RUN key rotation direction
40
selection
41
Up-to-frequency sensitivity
42
Output frequency detection
Output frequency detection for
43
reverse rotation
Second acceleration/
44
deceleration time
45
Second deceleration time
46
Second torque boost
47
Second V/F (base frequency)
Second stall prevention
48
operation current
Second electronic thermal O/L
51
relay
DU/PU main display data
52
selection
54
FM terminal function selection
Frequency monitoring
55
reference
56
Current monitoring reference
57
Restart coasting time
58
Restart cushion time
59
Remote function selection
Energy saving control
60
selection
61
Reference current
Reference value at
62
acceleration
Reference value at
63
deceleration
65
Retry selection
Parameter list
Setting
Initial
Range
Value
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0, 0.01 to
0
9998
0, 1
0
0 to 100%
10%
0 to 400Hz
6Hz
0 to 400Hz,
9999
9999
0 to 3600/
5/10/15s
360s

0 to 3600/
9999
360s, 9999
0 to 30%,
9999
9999
0 to 400Hz,
9999
9999
0 to 200%,
9999
9999
0 to 500A,
9999
9999
0, 5, 7 to 12,
14, 20,
23 to 25,
0
52 to 57, 61,
62, 100
1 to 3, 5,
7 to 12, 14,
1
21, 24, 52,
53, 61, 62
0 to 400Hz
60Hz
Inverter
0 to 500A
rated
current
0, 0.1 to 5s,
9999
9999
0 to 60s
1s
0, 1, 2, 3
0
0, 9
0
0 to 500A,
9999
9999
0 to 200%,
9999
9999
0 to 200%,
9999
9999
0 to 5
0
33
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents