Download Print this page
Aiphone NE-SS-1G Instructions

Aiphone NE-SS-1G Instructions

Vandal and weather resistant 1-gang sub station

Advertisement

Quick Links

Vandal and Weather Resistant 1-Gang Sub Station
The NE-SS-1G is a 1-gang vandal proof and weather resistant sub stations designed for use with the NEM, NDR and
NDRM systems. This unit is constructed of 12 gauge stainless steel and is equipped with an option for an external output
contact closure when the sub station places a call (relay required). The unit either flush mounts into a 1-gang box, or
surface mounts with the SBX-1G. Each unit includes tamper proof screws and a tool for installation.
INSTALLATION:
1. For flush mounting, install sub station in standard 1-gang electrical box with min. 2-1/2" depth.
2. For surface mounting, install sub station in the SBX-1G surface mount enclosure.
3. IMPORTANT! This unit is designed for use in normal weather conditions, and is made to allow for drainage and
evaporation of moisture that naturally gets into it. Do not apply caulking or silicone sealant around the unit
when installing, and do not use weather stripping around the perimeter of the box when mounting. If
sealing the unit is required, the bottom must remain unsealed. Sealing the unit will prevent or inhibit moisture from
dissipating from inside the unit, which may cause corrosion or deterioration to the internal components over time.
Warranty does not cover damage caused by sealing the unit.
CALL BUTTON WITH
CALL ASSURANCE LED
WIRING DIAGRAM:
NEM Master
1
2
3
~
20
PS-2420UL
E
+
+
-
-
H
duration of call-in
Page 1
- INSTRUCTIONS -
NE-SS-1G
SPEAKER
NE-SS-1G
Red
Blk
Blu
Blk
RY-PA
Dry closure
Yel
output for
WIRE DESIGNATIONS:
Red: + side of speaker. Connect to station number on master station.
Blue: Trigger for corridor lamp. 7V DC when call-in signal is activated.
Black: - side of speaker (common). Connect to E on master station.
White: Negative trigger wire for extra relay contact closure at sub during call-in.
Small wht & blk: Speaker connection to PCB
Small brn (x2): Call button connection to PCB
Back View
NE-SS-1G
(w/dry closure output)
Red
Blk
Blu
Wht
Blk
1- ⁄ "
15
16
2-⅞" 3-¼"
NE-SS-1G
(w/corridor lamp)
Red
Blk
Blu
NBY-4A
Blu
Blu

Advertisement

loading

Summary of Contents for Aiphone NE-SS-1G

  • Page 1 Vandal and Weather Resistant 1-Gang Sub Station The NE-SS-1G is a 1-gang vandal proof and weather resistant sub stations designed for use with the NEM, NDR and NDRM systems. This unit is constructed of 12 gauge stainless steel and is equipped with an option for an external output contact closure when the sub station places a call (relay required).