B-35
Parameter
P.503
Memory Button Disable
Disables the specified memory button(s). When a memory is disabled, welding procedures can-
not be restored from or saved to that memory. If an attempt is made to save or restore a dis-
abled memory, a message will be displayed on the lower display indicating the memory number
is disabled. In multi-head systems, this parameter disables the same memory buttons on both
feed heads. This parameter can only be accessed using Power Wave Manager software.
P.504
Mode Select Panel Lock
Selects between several Mode Select Panel lockout preferences. When a Mode Select Panel
selection is locked and an attempt is made to change that parameter, a message will be dis-
played on the lower display indicating the parameter is locked.
• All MSP Options Unlocked = All adjustable parameters on the Mode Select Panel are
unlocked.
• All MSP Options Locked = All knobs and buttons on the Mode Select Panel are locked.
• Start and End Options Locked = The Start and End parameters on the Mode Select Panel are
locked, all others are unlocked.
• Weld Mode Option Locked = The weld mode cannot be changed from the Mode Select Panel,
all others Mode Select Panel settings are unlocked.
• Wave Control Options Locked = The Wave Control parameters on the Mode Select Panel are
locked, all others are unlocked.
• Start, End, Wave Options Locked = The Start, End and Wave Control parameters on the
Mode Select Panel are locked, all others are unlocked.
• Start, End, Mode Options Locked = The Start, End and Weld Mode Select parameters on the
Mode Select Panel are locked, all others are unlocked.
• This parameter can only be accessed using Power Wave Manager software.
P.505
Setup Menu Lock
Determines if the setup parameters can be modified by the operator without entering a pass-
code.
No = The operator can change any set menu parameter without first entering the passcode
even if the passcode is non-zero (default).
Yes = The operator must enter the passcode (if the passcode is non-zero) in order to change
any setup menu parameters.
This parameter can only be accessed using Power Wave Manager software.
P.506
Set User Interface Passcode
Prevents unauthorized changes to the equipment. The default passcode is zero which allows
full access. A nonzero passcode will prevent unauthorized: changes to memory limits, saving
to memory (if P.502 = Yes), changes to setup parameters (if P.505 = Yes).
This parameter can only be accessed using Power Wave Manager software.
P.507
UI Clear All Memories
Allows the operator to quickly set all memories to the default weld mode and welding parame-
ters. Presently, this option does not exist in any setup menu.
P.509
UI Master Lockout
Locks all user interface controls, preventing the operator from making any changes. This para-
meter can only be accessed using Power Wave Manager.
OPERATION