DHW Inlet Temperature Sensor
(7850P-015)
Exhaust Temperature Sensor
(7850P-070)
o
Temperature (
F)
Resistance (Ω)
-4
62162
5
48440
14
38045
23
30107
32
23998
41
19261
50
15562
59
12655
68
10353
77
86
95
104
113
122
131
140
149
158
167
176
185
194
203
212
Table 37 - Temperature Sensor Resistance

Part 11 - Installation Checklist

Before Installing
Is there enough space to ensure proper installation?
Does installation location allow for proper service clearances?
Are water and gas lines properly sized and set at proper pressures for the installation?
Is water heater location as near the exhaust vent / intake pipe terminations as possible?
Have combustible materials been cleared from the installation location?
Is there a drain close to the water heater?
Water Piping
Does water heater loop piping meet the minimum sizing requirements listed?
NOTE: Smaller piping will cause performance problems.
Has water chemistry been checked?
Does water chemistry meet requirements?
If water chemistry does not meet requirements, have treatment measures been put in place?
Has the system been cleaned and flushed?
Install Exhaust Vent and Intake Piping
Has the water heater been vented with the approved materials listed in this manual or to meet local codes?
Is air supply sufficient for proper water heater operation?
Is total vent piping length within the maximum vent length restriction listed in this manual?
whl-004 Rev. 000 Rel. 013 Date 5.1.18
DHW Outlet Temperature Sensor
(7850P-019)
HX (OP) Temperature Sensor
(7850P-081)
Temperature (
-4
5
14
23
32
41
50
59
68
8520
77
7051
86
5867
95
4908
104
4125
113
3485
122
2957
131
2520
140
2157
149
1854
158
1600
167
1386
176
1205
185
1051
194
920
203
808
212
o
F)
Resistance (Ω)
28409
22152
17408
13782
10990
8824
7131
5800
4747
3906
3233
2690
2250
1891
1598
1356
1155
989
850
733
635
552
482
421
370
Figure 57 - Flame Sight Glass
Yes
Yes
Yes
No
No
No