Pioneer PRO-607PU Service Manual page 167

Hide thumbs Also See for PRO-607PU:
Table of Contents

Advertisement

1
6 CA CHECK
A
(From 5 )
Display RST MASK 05 (black).
Are there abnormal bright cells?
Check on the Factory menu to see if
B
each voltage setting is for the proper value.
Turn the Mask off:
Exit Factory mode:
CA check
C
Turn the unit off then back on again:
Use input signals from a DVD or PC for CA checking.
D
E
F
128
1
2
MKS S55
No
Yes
• If a PC is connected to the unit, issue the QAJ command to check each voltage.
QAJ
Example: Received data: QAJ136113026***128128128128128330F7
The numbers after QAJ represent each voltage after adjustment, as follows:
136: Vsus = 207 [V]
113: Vofs = 32 [V]
026: Vyprst = 250 [V]
MKS S00
FAN
Return to initial settings.
POF, PON
Check that no bright cells or dark cells.
PDP-6071PU
2
3
Replace the panel
again or abnormality
in circuits
3
4
4