3-20. Diagnostics consumers functions

Line
Access
8700
U
Outside temperature
Outside temperature minimum
8701
U
Reset? (no, yes)
Outside temperature maximum
8702
U
Reset? (no, yes)
Outside temperature attenuated
I
Reset? (no, yes)
8703
This is the average of the outside temperature over a 24-hour period. This value is used for
automatic Summer/Winter switchover (line 730).
I
Outside temperature composite
The mixed outside temperature is a combination of the current outside temperature and the
8704
average outside temperature calculated by the regulator. This value is used for calculating the initial
temperature.
8730
I
Heating circuit pump, circuit 1
8731
I
Mixer valve HC1 open
8732
I
Mixer valve HC1 closed
Room temperature 1
8740
U
Room setting 1
Flow temperature 1
8743
U
Flow temperature setpoint 1
8749
I
Room thermostat 1
Cooling flow temperature 1
8756
U
Cooling flow temperature setpoint 1
8820
I
DHW pump
8821
I
Electric immersion heater DHW
DHW temperature
8830
U
DHW temperature setpoint
8832
I
DHW temperature 2
8840
S
Hours run DHW pump
8841
S
Start counter DHW pump
8842
S
Hours run electric DHW
8843
S
Start counter electric DHW
Common flow temperature
8950
I
Common flow temperature setpoint
8957
I
Common flow setpoint refrigerant
9005
I
Water pressure 1
9006
I
Water pressure 2
9009
I
Water pressure 3
9010
I
Measurement room temperature 1
9011
I
Measurement room temperature 2
9031
I
Relay output QX1
9032
I
Relay output QX2
9033
I
Relay output QX3
9034
I
Relay output QX4
9035
I
Relay output QX5
Various setpoints and actual values, relay switch status and timing data can be displayed for pur-
pose of diagnosis.
3-20. Diagnostics consumers functions
Function
-50...50°C
-50...50°C
-50...50°C
-50...50°C
-50...50°C
Off, On
Off, On
Off, On
0...50 °C
0....140 °C
No demand, Demand
0...140 °C
Off, On
Off, On
0...140 °C
0...140 °C
0...2730h
0...199999
0...2730 h
0...65535
0...140°C
0...140°C
-100...500 bar
-100...500 bar
-100...500 bar
0...50 °C
0...50 °C
Off, On
Off, On
Off, On
Off, On
Off, On
- (03-64) -
Setting range or display
Factory
setting
---
50°C
-50°C
---
---
Off
Off
Off
---
20°C
---
---
No demand
---
---
Off
Off
---
50°C
---
---
---
---
---
---
---
---
---
---
---
---
---
On
On
On
Off
Off
3. Function table