Graco Sherwin-Williams ULTIMATE Mx 795 Owner's Manual page 30

Airless paint sprayer
Hide thumbs Also See for Sherwin-Williams ULTIMATE Mx 795:
Table of Contents

Advertisement

Displacement Pump Repair
Installing pump
WARNING
If the pin works loose, it or other parts could break
off due to the force of the pumping action. These
parts could be projected through the air and result
in serious bodily injury or property damage, includ-
ing damage to the pump, connecting rod or bearing
housing.
CAUTION
If the pump locknut loosens during operation, the
threads of the bearing housing will be damaged.
1. Fig. 24. Pull piston rod out 1.5 in. Screw in pump
until holes in bearing cross link and piston rod
align.
Fig. 24
2. Fig. 25. Push pin (21) into holes.
Fig. 25
3. Fig. 26. Push retaining spring into groove all the
way around connecting rod.
Fig. 26
Fig. 27. Screw jam nut down onto pump until stops.
Screw pump up into bearing housing until it is stopped
by jam nut. Back off pump and jam nut to align pump
outlet to back. Tighten jam nut by hand, then tap 1/8 to
1/4 turn with a 20 oz (maximum) hammer to approxi-
mately 75
7722A
Fig. 27
Fig. 28. Fill packing nut with Graco TSL, through one
of the slits, until fluid flows onto the top of seal.
21
7720A
Fig. 28
5 ft–lb (102 N m).
7719A
7723A
7710A

Advertisement

Table of Contents
loading

This manual is also suitable for:

824-140

Table of Contents