Sony FCB-EX2400 Technical Manual page 36

Color camera module
Table of Contents

Advertisement

VISCA Camera-Issued Messages
Acknowledge/Completion Messages
Acknowledge
Completion
z = Device address + 8
Error Messages
Syntax Error
Command Buffer Full
Command Canceled
No Socket
Command Not Executable
Network Change Message
Network Change
Command Messages
z0 4y FF
(y:Socket No.)
z0 5y FF
(y:Socket No.)
Command Messages
z0 60 02 FF
z0 60 03 FF
z0 6y 04 FF
(y:Socket No.)
z0 6y 05 FF
(y:Socket No.)
z0 6y 41 FF
(y:Socket No.)
Command Messages
z0 38 FF
Comments
Returned when the command is accepted.
Returned when the command has been executed.
Comments
Returned when the command format is different or when a command with
illegal command parameters is accepted.
Indicates that two sockets are already being used (executing two
commands) and the command could not be accepted when received.
Returned when a command which is being executed in a socket specified
by the cancel command is canceled. The completion message for the
command which is being executed is not returned.
Returned when no command is executed in a socket specified by the
cancel command, or when an invalid socket number is specified.
Returned when a command cannot be executed due to current conditions.
For example, when commands controlling the focus manually are received
during auto focus.
Comments
Issued when power is being routed.