Sony FCB-EX2400 Technical Manual page 20

Color camera module
Table of Contents

Advertisement

Non Interlock Mask
Command: 8x 01 04 6F mm 0p 0p 0q 0q 0r 0r 0s 0s
FF
Parameter:
mm
Setting Mask
See "mm: Mask setting list" in "Parameters" on page 18.
pp
Sets the center position "x" of the Mask on screen.
qq
Sets the center position "y" of the Mask on screen.
rr
Sets the half value "w" of the Mask Width.
ss
Sets the half value "h" of the Mask Height.
See "pp: x, qq: y, rr: w, ss: h" in "Parameters" on page 18.
Comments: Mask does not interlock with pan/tilt.
The limitations of parameters are as follows.
(hexadecimal representation)
x: ±50h
w: ±50h
y: ±3ch
h: ±3ch
Note
When the Set Mask command and the Non Interlock Mask
command are set to the same mask, the command set later
becomes effective.
Grid
Use the grid displayed on the screen to set mask
positions (see the figure below).
By executing the Center Line On command, only the x
and y axes of the center are displayed. Grids lines
disappear.
Motion Detection Function
This function instructs the camera to detect movement
within the monitoring area and then send an alarm
signal automatically.
The detected signal goes out through the serial
communication line (VISCA command).
Features
Y ou can set a frame for the detection range of 12
(horizontally) × 8 (vertically) blocks.
Y ou can set up to four frames.
W hen the motion is detected in the set frame, the
Alarm Replay VISCA command is sent.
T he threshold level for detection can be set (common
to four frames).
T he interval of alarm detection can be set up to 256
seconds in units of one second.
Y ou can set on/off for each frame.
T he frame number is also sent with Alarm Replay to
report in which frame the motion has been detected.
Frames
Setting frames
You can set the frame by assigning the starting point
and terminating point vertically and horizontally. You
can set up to four frames.
When motion is detected within the range where
frames overlap
The alarms are sent for both frames.
14hex (20(10))
14hex (20(10))
Frame 1
Frame 2
Frame 3
Frame 4
At this position, the
alarm for frame 3 is sent.
Basic Functions
Within this overlapped
range, alarms are sent for
both frame 3 and frame 4.
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fcb-ex2400p

Table of Contents