■Definition and terminology

Terms
2
2-colour display
7
7-segment display
A
Analogue current output
Analogue output function
Analogue voltage output
Auto preset
Auto shift
B
Bottom value display
C
Chattering
Chattering preventing function
D
Digit (Minimum setting unit)
E
Error indication
F
Fine adjustment mode
Fine adjustment of display
value
F.S. (full span/full scale)
Function selection mode
H
Hysteresis
Hysteresis mode
2 colours are used to indicate a value, which change according to the output
status.
When "8" is shown on the display. It is called 7-segment because 8 consists of 7
pieces of "- (segments)".
Refer to "Analogue output (function)".
A function to output the voltage or current in proportion to the pressure.
Refer to "Analogue output (function)".
A function to automatically set up the pressure by having equipment hold and
release a workpiece via vacuum adsorption. This function is used in an
application where vacuum adsorption of a workpiece is confirmed by a Pressure
switch.
A function to correct the set value of the switch output in accordance with the
applied pressure in case the switch operation is unstable due to pulsation of
applied pressure. This function is used in applications such as vacuum
adsorption. The pressure when a signal is externally input is set as a reference
value with which the pressure that turns the switch on or off can be shifted.
Indicates the minimum pressure reached up to that moment.
The problem of the switch output turning ON and OFF repeatedly around the set
value at high frequency due to the effect of pulsation.
A function to delay the response time of switch output in order to prevent
chattering.
Shows how precisely the pressure can be indicated or set by the digital Pressure
switch. When 1 digit = 1 kPa, the pressure is given with an increment of 1 kPa,
e.g., 1, 2, 3, ..., 99, 100.
With the self-diagnostic function of the Pressure switch, this indicates that there
is an error which could cause a switch failure.
Refer to "Fine adjustment of display value".
A displayed pressure value can be adjusted within the range of ±5% R.D.
(±5% of the displayed value). It is used if a true pressure value is known or to
correct the difference of a displayed value of the measurement equipment
nearby which measures the same pressure.
Abbreviation for full span or full scale; this means the maximum fluctuation range
of the Pressure switch rated value. For example, when the output voltage is 1 to
5[V], the F.S. will be 5-1 = 4[V]. (Ref: 1% F.S. = 4 × 0.01 = 0.04[V])
This is a mode in which each function is set up, and is a separate menu from the
pressure setup. If the setting needs to be changed, "F∗", each item can be set
up. The items to be set up are: display colour, operation mode, output type,
response time, display resolution, fine adjustment of indicated value, auto preset,
power-saving mode and security code number.
The difference between the pressure switch ON and OFF points, used to prevent
chattering
Refer to "List of output modes" on page 26.